{"product_id":"20g11nc011ja0nnnnn-allen-bradley-ac-drive-powerflex-753","title":"20G11NC011JA0NNNNN Allen-Bradley AC Drive PowerFlex 753","description":"\u003cp\u003eConfigured for precision motor velocity and torque regulation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20G11NC011JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e20G11NC011JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct electrical execution of power conversion for three-phase induction and permanent magnet motor control.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix \u0026amp; Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 20G11NC011JA0NNNNN represents a PowerFlex 753 hardware build designed for 400 VAC or 540 VDC input bus applications. The unit features integrated precharge circuitry to manage inrush current, internal transistors for dynamic braking support, and an open-type IP20\/IP00 chassis architecture optimized for installation within protected electrical cabinets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20G11NC011JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 deg C to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kW (5 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 VAC \/ 540 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.7 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Drive Control Attributes\u003c\/h3\u003e\n\u003cp\u003eThe drive architecture leverages high-speed backplane bus communication to ensure deterministic performance across EtherNet\/IP and CIP motion networks. The unit supports firmware flash compatibility, facilitating the deployment of optimized motor control algorithms. Integrated I\/O density can be extended via plug-in option modules, allowing for modular scaling of control feedback loops and synchronization tasks.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 20G11NC011JA0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Terminal block connector set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Management:\u003c\/p\u003e\n\u003cp\u003eEnsure the drive is mounted in a vertical orientation. Maintain a minimum of 15 cm of clearance above and below the chassis to facilitate convective heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Shielding:\u003c\/p\u003e\n\u003cp\u003eUtilize shielded twisted-pair cabling for all analog reference and encoder feedback signals to mitigate the impact of electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Strategy:\u003c\/p\u003e\n\u003cp\u003eEstablish a low-impedance connection between the chassis protective earth (PE) terminal and the main equipment grounding bar to ensure potential reference stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling Segregation:\u003c\/p\u003e\n\u003cp\u003eMaintain physical separation between high-voltage power leads and low-voltage control signal conductors to prevent capacitive coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan the drive be hot-swapped while the DC bus is energized?\u003c\/p\u003e\n\u003cp\u003eNo. The input power must be removed and the DC bus capacitors must be verified to be at zero voltage before performing any physical installation or maintenance tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the Human Interface Module (HIM) required for operation?\u003c\/p\u003e\n\u003cp\u003eNo. The drive can be configured and monitored via network communication or connected engineering software tools; the HIM is optional and not included in this build.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this unit support common DC bus operation?\u003c\/p\u003e\n\u003cp\u003eYes. The drive is rated for 540 VDC input, allowing for integration into common DC bus systems provided the precharge sequence is managed correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the role of the internal precharge circuit?\u003c\/p\u003e\n\u003cp\u003eThe precharge circuit limits the peak charging current to the internal DC bus capacitors, protecting the input rectifier components during power-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the output current limit be adjusted?\u003c\/p\u003e\n\u003cp\u003eYes. The current limit is a configurable parameter within the drive firmware, allowing users to define protection thresholds based on the connected motor's thermal limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the drive retain parameters after a power loss?\u003c\/p\u003e\n\u003cp\u003eYes. All drive configuration data and parameters are saved to non-volatile memory (EEPROM) upon modification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the constraints of the IP00 enclosure?\u003c\/p\u003e\n\u003cp\u003eIP00 provides no environmental protection. The drive must be installed inside an enclosure rated for the specific operating environment to prevent ingress of contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the firmware be upgraded in the field?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware can be updated via the drive's communication port using standard configuration software provided by the manufacturer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066469929133,"sku":"20G11NC011JA0NNNNN","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20G11Nc8-1_ff69e10e-0d88-49fa-853c-93acbbdc45f5.jpg?v=1782295839","url":"https:\/\/www.maxwellplc.com\/products\/20g11nc011ja0nnnnn-allen-bradley-ac-drive-powerflex-753","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}