{"product_id":"20f1anf263jn0nnnnn-allen-bradley-ac-drive-powerflex-753","title":"20F1ANF263JN0NNNNN Allen-Bradley AC Drive PowerFlex 753","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F1ANF263JN0NNNNN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20F1ANF263JN0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive, operates as a dedicated hardware component for high-power induction motor speed and torque regulation within industrial drive platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 20F1ANF263JN0NNNNN designates a PowerFlex 753 air-cooled drive rated for 690 VAC or 932 VDC input supply. The unit incorporates precharge circuitry to manage power-on inrush currents and includes output filtering. This hardware build is housed in an IP20\/IP00 open-type chassis and does not contain an internal dynamic braking transistor or a Human Interface Module (HIM).\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F1ANF263JN0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 deg C to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 kW (335 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e690 VAC \/ 932 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e263 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Drive Control Attributes\u003c\/h3\u003e\n\u003cp\u003eThe drive architecture utilizes a high-speed backplane bus to support deterministic Profinet and EtherNet\/IP communication networks. Firmware flash compatibility allows for granular updates to the internal control loops and motor protection algorithms. I\/O density can be scaled through the installation of option modules, facilitating synchronization with external control systems and multi-drive coordination.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 20F1ANF263JN0NNNNN AC Drive Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Terminal block connector kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Mitigation:\u003c\/p\u003e\n\u003cp\u003eInstall in a clean environment with vertical orientation. Ensure forced-air ventilation systems are operational to maintain heat sink temperatures within the specified limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Wiring:\u003c\/p\u003e\n\u003cp\u003eUtilize appropriately rated cabling for 690 VAC applications. Route power conductors away from control signal cables to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Protocol:\u003c\/p\u003e\n\u003cp\u003eConnect the drive chassis to a common earth ground using a low-impedance conductor to stabilize the system potential and satisfy safety requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Clearance:\u003c\/p\u003e\n\u003cp\u003eProvide adequate spatial clearance as defined in the technical manual for air intake and exhaust to prevent localized thermal throttling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this unit support dynamic braking?\u003c\/p\u003e\n\u003cp\u003eNo. This specific part number does not include an internal dynamic braking transistor. External braking hardware or alternative drive configurations are required for such applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 20F1ANF263JN0NNNNN compatible with single-phase input?\u003c\/p\u003e\n\u003cp\u003eNo. This drive is designed specifically for three-phase AC input or high-voltage DC bus input. Single-phase application will result in input phase loss faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the drive be operated without the installed jumper?\u003c\/p\u003e\n\u003cp\u003eNo. The factory-installed jumper is required to complete the internal safety and precharge circuitry. Removal without an equivalent external bridge will prevent operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs there a HIM included in the package?\u003c\/p\u003e\n\u003cp\u003eNo. This model is supplied without a Human Interface Module. Configuration must be performed via external software tools or a separately procured HIM.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the input voltage exceeds 690 VAC?\u003c\/p\u003e\n\u003cp\u003eExceeding the rated input voltage will trigger overvoltage protection faults and may cause permanent damage to the input rectifier components and capacitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs it possible to hot-swap this drive module?\u003c\/p\u003e\n\u003cp\u003eNo. The unit must be fully de-energized, and the DC bus must be verified as discharged to 0 V before any physical extraction or terminal work is performed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre internal fuses user-replaceable?\u003c\/p\u003e\n\u003cp\u003eNo. The drive is a field-replaceable unit (FRU). There are no user-serviceable fuses internal to the drive chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware updated?\u003c\/p\u003e\n\u003cp\u003eFirmware updates are conducted via the communication ports using the manufacturer's engineering software, which supports localized flash memory writing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066469863597,"sku":"20F1ANF263JN0NNNNN","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-1.jpg?v=1782440891","url":"https:\/\/www.maxwellplc.com\/products\/20f1anf263jn0nnnnn-allen-bradley-ac-drive-powerflex-753","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}