{"product_id":"20f1and248ja0nnnnn-allen-bradley-powerflex-753-ac-drive-module","title":"20F1AND248JA0NNNNN Allen-Bradley PowerFlex 753 AC Drive Module","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F1AND248JA0NNNNN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20F1AND248JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive, operates as a dedicated hardware component for variable frequency motor control within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edrive platform. It provides three-phase motor control through AC input precharge circuitry, embedded I\/O, and integrated drive functions for closed-loop and open-loop industrial applications.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cp\u003eThe complete catalog number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20F1AND248JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents a factory-defined configuration of the Allen-Bradley PowerFlex 753 AC Drive. Parameters including voltage class, enclosure type, frame size, EMC filtering, cooling method, dynamic braking capability, and embedded I\/O are determined by the complete catalog number. Individual suffix characters should be interpreted according to official Allen-Bradley documentation rather than separated into independent option codes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e20F1AND248JA0NNNNN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 753 AC Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 753\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Frequency AC Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulletin Number\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 753 AC Drive with Embedded I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Class\u003c\/td\u003e\n\u003ctd\u003e480 VAC, 3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e650 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e186 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Duty Rating\u003c\/td\u003e\n\u003ctd\u003e150 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeavy Duty Rating\u003c\/td\u003e\n\u003ctd\u003e125 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eForced Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Gas Protection\u003c\/td\u003e\n\u003ctd\u003eStandard Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFrame 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eAC Input with Precharge, No DC Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Filtering\u003c\/td\u003e\n\u003ctd\u003eFiltered, CM Jumper Installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Braking\u003c\/td\u003e\n\u003ctd\u003eIntegrated DB Transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded I\/O\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e29.5 x 40.5 x 17.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eRefer to manufacturer documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDepends on connected motor load and operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFirmware Compatibility and Industrial Network Integration\u003c\/h3\u003e\n\u003cp\u003ePowerFlex 753 drives support integration within Allen-Bradley automation architectures through optional industrial communication adapters and embedded control functions. Firmware revision compatibility should be verified before replacing an existing drive or restoring parameter files. Matching firmware revisions help maintain communication consistency between the drive, controller, and engineering software. Network configuration should follow the communication module installed within the drive system.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePackage contents normally include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Allen-Bradley 20F1AND248JA0NNNNN PowerFlex 753 AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Factory-installed Embedded I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Integrated EMC Filter Configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Integrated Dynamic Braking Transistor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Product Identification Label\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Manufacturer Documentation (when supplied)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional accessories may include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHuman Interface Module (HIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEtherNet\/IP Communication Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl I\/O Expansion Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBrake Resistor Assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLine Reactors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Reactors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEMC Accessories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement Cooling Fan Kits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDrive Installation Recommendations\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the drive in the vertical orientation specified by the manufacturer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain sufficient clearance above and below the cooling fan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall inside an enclosure suitable for the operating environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep ventilation passages free from dust accumulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Wiring\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the supply voltage matches the drive nameplate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolate incoming power before performing wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse appropriately rated conductors and protective devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect protective earth before energizing the equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate motor cables from control cables where practical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl Wiring\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute analog and digital signal wiring separately from power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround cable shields according to the system grounding strategy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify terminal tightening torque before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck embedded I\/O assignments prior to controller download.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommissioning\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnter motor nameplate data before the initial startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm communication parameters with the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify braking configuration if an external resistor is installed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform functional testing before placing the drive into production service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the PowerFlex 753 be replaced while input power remains energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Remove incoming power completely and allow the DC bus to discharge before servicing or replacing the drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive include embedded I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The specified catalog number is supplied with factory-installed embedded I\/O for standard control functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs firmware compatibility important during replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Firmware revisions should match project requirements to maintain parameter compatibility and communication performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan additional communication modules be installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Supported communication adapters may be installed according to the available option slots and system design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the EMC filter included with this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This configuration includes a filtered version with the CM jumper installed from the factory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the drive operate without an external braking resistor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The integrated DB transistor supports external braking hardware when application requirements demand additional braking energy dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShould motor and encoder cables be installed together?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Signal wiring should be separated from motor power wiring to reduce electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be verified before commissioning a replacement drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify firmware revision, parameter configuration, motor data, communication settings, protective grounding, and field wiring before energizing the equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066468192429,"sku":"20F1AND248JA0NNNNN","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-1_4acdcd8e-c67d-43fe-9edd-a0916a7cc144.jpg?v=1782441667","url":"https:\/\/www.maxwellplc.com\/products\/20f1and248ja0nnnnn-allen-bradley-powerflex-753-ac-drive-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}