{"product_id":"20f11rc5p0aa0nnnnn-allen-bradley-powerflex-753-ac-drive","title":"20F11RC5P0AA0NNNNN Allen-Bradley PowerFlex 753 AC Drive","description":"\u003cp\u003eConfigured for high-precision motor velocity and torque regulation in EtherNet\/IP networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F11RC5P0AA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e20F11RC5P0AA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct electrical execution of power conversion for induction motor control.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 20F11RC5P0AA0NNNNN is a PowerFlex 753 frame 1 hardware assembly rated for 400 VAC input. This unit incorporates internal DC terminal access, integrated filtering for EMC compliance, and a dedicated dynamic braking (DB) transistor. The architecture is housed in an IP20\/IP00 open-type chassis, featuring embedded I\/O blocks for direct control loop integration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F11RC5P0AA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 deg C to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kW (Normal Duty) \/ 5.5 kW (Heavy Duty)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.4 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Network Communication\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 platform utilizes high-speed backplane bus communication to maintain deterministic performance across EtherNet\/IP and CIP motion networks. The hardware supports firmware flash compatibility, allowing localized updates to motor control algorithms and protective logic. Modular option cards enable I\/O density scaling, ensuring precise synchronization of drive axes within multi-drive automation systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 20F11RC5P0AA0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Terminal block connector set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Management:\u003c\/p\u003e\n\u003cp\u003eMount the frame 1 chassis in a vertical orientation. Ensure clear airflow paths through the internal heat sink to maintain operating temperatures within the specified -10 deg C to 50 deg C range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding \u0026amp; Shielding:\u003c\/p\u003e\n\u003cp\u003eEstablish a low-impedance connection between the chassis protective earth (PE) terminal and the main equipment grounding bar to ensure potential reference stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling Segregation:\u003c\/p\u003e\n\u003cp\u003eMaintain physical separation between high-voltage power leads and low-voltage control signals to mitigate electromagnetic interference and capacitive coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Protection:\u003c\/p\u003e\n\u003cp\u003eIP20\/IP00 enclosures lack ingress protection against fine dust or moisture. Install within a NEMA\/UL-compliant secondary cabinet to preserve hardware integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model support external DC bus sharing?\u003c\/p\u003e\n\u003cp\u003eYes. The inclusion of DC terminals allows for common DC bus configurations, provided the precharge sequence is managed to protect the internal input rectifier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the DB transistor capable of continuous energy dissipation?\u003c\/p\u003e\n\u003cp\u003eNo. The DB transistor is intended for cyclical braking. Ensure external resistors are sized for the specific peak and average regenerative power of the application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the CM jumper managed?\u003c\/p\u003e\n\u003cp\u003eThe CM jumper is factory-installed to provide common-mode filtering; it should remain in place unless specific site grounding requirements dictate removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan firmware be updated remotely?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware can be flashed via the communication port using the manufacturer's engineering software tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the drive compatible with single-phase input?\u003c\/p\u003e\n\u003cp\u003eNo. The drive requires 400 VAC 3-phase input for proper rectifier operation and DC bus voltage levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the embedded I\/O be expanded?\u003c\/p\u003e\n\u003cp\u003eYes. Additional I\/O density can be achieved by installing optional plugin modules into the available drive slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response latency of the backplane bus?\u003c\/p\u003e\n\u003cp\u003eThe backplane bus operates with deterministic latency suitable for high-speed CIP motion and synchronization tasks within the drive ecosystem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre internal fuses user-replaceable?\u003c\/p\u003e\n\u003cp\u003eNo. The drive is a field-replaceable unit. There are no user-serviceable fuses or components located inside the chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066465112237,"sku":"20F11RC5P0AA0NNNNN","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-15.jpg?v=1782445425","url":"https:\/\/www.maxwellplc.com\/products\/20f11rc5p0aa0nnnnn-allen-bradley-powerflex-753-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}