{"product_id":"20f11nd077ja0nnnnn-allen-bradley-powerflex-753-ac-drive","title":"20F11ND077JA0NNNNN Allen-Bradley PowerFlex 753 AC Drive","description":"\u003cp\u003eConfigured for high-power motor control in industrial automation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F11ND077JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e20F11ND077JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct physical\/electrical execution. This PowerFlex 753 drive operates with 480 VAC, 3-phase input and features integrated I\/O functionality for localized machine control. The unit utilizes a Frame 5 chassis with standard forced-air cooling, supporting both normal duty and heavy duty application requirements through its variable output current profiles.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix \u0026amp; Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20F\u003c\/strong\u003e: PowerFlex 753 drive series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e11N\u003c\/strong\u003e: 480 VAC, 3-phase input with DC terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eD077\u003c\/strong\u003e: 77 Amps continuous output current (ND).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJ\u003c\/strong\u003e: Frame 5 chassis size.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA0\u003c\/strong\u003e: Filtered EMC option with CM jumper installed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eN\u003c\/strong\u003e: Standard protection and forced-air cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eN\u003c\/strong\u003e: Blank HIM (Human Interface Module).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNNN\u003c\/strong\u003e: No additional factory-installed options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F11ND077JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 cm x 40.5 cm x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e480 VAC \/ 650 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current (ND)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e77 A (60 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current (HD)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 A (50 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ IP00 (Open Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Industrial Network Control\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 series is engineered for seamless integration into high-speed industrial networks, utilizing EtherNet\/IP and related protocols to maintain deterministic communication. The architecture supports advanced I\/O density scaling, allowing for the precise configuration of input and output points via the internal backplane bus. Firmware flash compatibility is included, permitting field-side updates to communication stacks and motor control algorithms. This design ensures that motion profiles and setpoints remain synchronized across multi-axis platforms, minimizing command-to-execution latency within the control network.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 20F11ND077JA0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 I\/O terminal block kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Technical installation and safety manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the unit vertically on a rigid, flat surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain minimum airflow clearance zones above and below the Frame 5 chassis to support effective forced-air cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate all power input and motor leads to the drive’s terminals following specified torque values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEstablish a robust connection to the facility earth ground to optimize EMC performance and maintain the functional integrity of the installed CM jumper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this drive support hot-swappable I\/O modules?\u003c\/p\u003e\n\u003cp\u003eNo, all I\/O cards and control modules must be installed or removed while the drive is de-energized to prevent electrical damage to the backplane communication pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the difference between ND and HD modes?\u003c\/p\u003e\n\u003cp\u003eND (Normal Duty) supports 77 A for standard constant torque applications, while HD (Heavy Duty) supports 65 A with increased overload capacity for demanding start cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the CM jumper be removed?\u003c\/p\u003e\n\u003cp\u003eThe CM jumper is factory-configured for optimal EMC performance; removing it may increase electrical noise levels and violate regulatory electromagnetic compatibility standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the HIM added if it is currently blank?\u003c\/p\u003e\n\u003cp\u003eA standard PowerFlex 753 HIM can be attached to the front of the drive at any time to provide a local human-machine interface for programming and diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat protection is provided by the open-type enclosure?\u003c\/p\u003e\n\u003cp\u003eThe IP20 open-type enclosure provides limited protection against solid objects larger than 12 mm; it requires installation within a controlled, NEMA-rated cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware updated?\u003c\/p\u003e\n\u003cp\u003eFirmware updates are performed using the ControlFLASH utility through the drive's communication port; ensure the system is in a safe state before initiating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat triggers the internal thermal fault?\u003c\/p\u003e\n\u003cp\u003eThe drive monitors the heatsink temperature; if airflow is blocked or ambient temperature exceeds limits, it will cease operation to protect internal power electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the DC terminals be used for power supply?\u003c\/p\u003e\n\u003cp\u003eThe DC terminals are intended for DC bus sharing or connection to an external braking resistor; do not connect them to an external AC power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066464424109,"sku":"20F11ND077JA0NNNNN","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-48_e681bade-7a7e-4de8-be8a-6acf48b47066.jpg?v=1782446044","url":"https:\/\/www.maxwellplc.com\/products\/20f11nd077ja0nnnnn-allen-bradley-powerflex-753-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}