{"product_id":"2080-serialisol-allen-bradley-micrologix-isolated-serial-port","title":"2080-SERIALISOL Allen-Bradley MicroLogix Isolated Serial Port","description":"\u003cp\u003eConfigured for serial communication isolation in Micro800 control architectures, the \u003cstrong\u003eAllen-Bradley 2080-SERIALISOL\u003c\/strong\u003e (\u003cstrong\u003e2080-SERIALISOL\u003c\/strong\u003e Isolated Serial Port) provides direct physical signal protection for RS-232\/485 serial loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2080-SERIALISOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e16.5 x 16.5 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e0.2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.22-0.25 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.0 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe module is engineered to support industrial-grade communication protocols within the EtherNet\/IP and serial network ecosystem. By providing galvanic isolation, the hardware ensures that backplane bus communication velocity remains stable while mitigating ground loop potential between the controller and remote field devices. Compatibility with standard firmware flash routines allows for configuration updates without requiring structural changes to the established deterministic network topology.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e2080-SERIALISOL Isolated Serial Port Module\u003c\/li\u003e\n\u003cli\u003e1 Set of terminal block connectors\u003c\/li\u003e\n\u003cli\u003e1 Technical manual\/instruction sheet\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: Ensure the module is fully seated in the plug-in slot before tightening the mounting screws to 0.2 Nm.\u003c\/li\u003e\n\u003cli\u003eTerminal Wiring: Use specified screwdriver bits to apply 0.22-0.25 Nm torque to terminal screws; verify wire gauge limits to prevent mechanical stress on the PCB headers.\u003c\/li\u003e\n\u003cli\u003eGrounding: Maintain a clear path to the functional earth terminal to ensure the 500 V AC isolation barrier performs according to specifications.\u003c\/li\u003e\n\u003cli\u003eShielding: Use shielded cabling for all serial runs to prevent cross-talk in high-frequency noise environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the 500 V AC isolation?\u003c\/p\u003e\n\u003cp\u003eThe isolation barrier protects the controller's internal circuitry from voltage spikes or ground potential differences that may exist on the connected serial network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module require external power?\u003c\/p\u003e\n\u003cp\u003eNo, the module derives its operational power directly from the Micro800 controller backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this module compatible with all Micro800 controllers?\u003c\/p\u003e\n\u003cp\u003eCompatibility is dependent on the specific base unit's plug-in slot availability; verify the controller hardware revision before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this module for RS-485 communication?\u003c\/p\u003e\n\u003cp\u003eYes, the module is designed to support standard RS-485 serial communication protocols, provided the wiring matches the interface specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum ambient temperature for operation?\u003c\/p\u003e\n\u003cp\u003eThe maximum surrounding air temperature is 65 deg C. Exceeding this limit will accelerate component degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the cable shield be terminated?\u003c\/p\u003e\n\u003cp\u003eShields should be connected to the functional ground point at the module end to effectively dissipate induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there any firmware requirements for this module?\u003c\/p\u003e\n\u003cp\u003eNo specific firmware is loaded on the module; it is recognized by the controller through the standard plug-in identification protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is precise torque required on the terminal screws?\u003c\/p\u003e\n\u003cp\u003eProper torque ensures low contact resistance and prevents mechanical loosening due to industrial vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066460426413,"sku":"2080-SERIALISOL","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen_bradley_2080-serialisol_1.jpg?v=1783868833","url":"https:\/\/www.maxwellplc.com\/products\/2080-serialisol-allen-bradley-micrologix-isolated-serial-port","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}