{"product_id":"200152-15-00-bently-nevada-accelerometer-interface-standard-cable-iepe-series","title":"200152-15-00 Bently Nevada Accelerometer Interface Standard Cable IEPE Series","description":"\u003cp\u003eConfigured for accelerometer signal connection in Bently Nevada vibration monitoring systems, the \u003cstrong\u003eBently Nevada 200152-15-00\u003c\/strong\u003e (\u003cstrong\u003e200152\u003c\/strong\u003e Accelerometer Interface Standard Cable) provides direct electrical interface between accelerometer assemblies and monitoring hardware.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Overview\u003c\/h3\u003e\n\u003cp\u003eThe 200152-15-00 is a 15 meter standard accelerometer cable configuration with a standard coupling nut. The cable is designed for Bently Nevada IEPE accelerometer interfaces and provides electrical connection for piezoelectric vibration sensing devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e200152-15-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAccelerometer Interface Standard Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eIEPE Accelerometer Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.8 x 3.5 x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Design\u003c\/td\u003e\n\u003ctd\u003eStandard Cable, No Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling Type\u003c\/td\u003e\n\u003ctd\u003eStandard coupling nut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003eConnector on accelerometer end only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity @80 Hz\u003c\/td\u003e\n\u003ctd\u003e10.2 mV\/(m\/s2) (100 mV\/g) +\/-12%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Voltage\u003c\/td\u003e\n\u003ctd\u003e4.7 to 5.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuiescent Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;800 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Bias Voltage\u003c\/td\u003e\n\u003ctd\u003e+2.5 +\/-0.23 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIEPE Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 200152-15-00 cable is designed for IEPE accelerometer signal transmission where the connected sensor requires constant current excitation and outputs a voltage signal proportional to vibration acceleration.\u003c\/p\u003e\n\u003cp\u003eBently Nevada accelerometer systems use piezoelectric sensing elements that generate electrical charge under mechanical vibration. The interface cable maintains the connection between the sensing element and monitoring electronics while supporting excitation voltage supply and signal return.\u003c\/p\u003e\n\u003cp\u003eFor mechanical monitoring applications, proper cable routing reduces electromagnetic interference and maintains measurement signal quality. Unlike eddy-current proximity probes that require gap voltage validation and probe scaling adjustment, IEPE accelerometer systems operate through powered piezoelectric signal interfaces.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 200152-15-00 Accelerometer Interface Standard Cable\u003c\/li\u003e\n\u003cli\u003eCable length: 15 m\u003c\/li\u003e\n\u003cli\u003eStandard coupling nut configuration\u003c\/li\u003e\n\u003cli\u003eConnector installed on accelerometer end only\u003c\/li\u003e\n\u003cli\u003eCable assembly for IEPE accelerometer interface applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the cable according to the connected accelerometer and monitoring system requirements.\u003c\/li\u003e\n\u003cli\u003eKeep signal cables separated from high-current power wiring.\u003c\/li\u003e\n\u003cli\u003eMaintain connector cleanliness during installation to prevent signal interruption.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive mechanical loading on the cable connector area.\u003c\/li\u003e\n\u003cli\u003eVerify excitation voltage availability from the connected monitoring interface.\u003c\/li\u003e\n\u003cli\u003eConfirm cable connection polarity and interface compatibility before operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the main function of the 200152-15-00 cable?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable provides electrical connection between Bently Nevada IEPE accelerometers and compatible vibration monitoring interfaces.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat type of accelerometer system uses this cable?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is designed for IEPE accelerometer series applications using powered piezoelectric sensing technology.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the cable length of this model?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 200152-15-00 configuration provides a 15 meter cable length.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this cable provide sensor excitation voltage?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable transfers the excitation voltage supplied by the connected monitoring interface to the accelerometer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the specified excitation voltage range?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe compatible excitation voltage range is 4.7 to 5.5 VDC according to the provided specification.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat type of signal does the connected accelerometer output?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe accelerometer provides a voltage output proportional to vibration acceleration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this cable include armor protection?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. The 200152-15-00 is specified as a standard cable without armor design.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat installation factors affect signal quality?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCable routing, connector condition, grounding practice, and separation from interference sources affect signal quality.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025259712685,"sku":"200152-15-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/200152-15-00-0.jpg?v=1785986345","url":"https:\/\/www.maxwellplc.com\/products\/200152-15-00-bently-nevada-accelerometer-interface-standard-cable-iepe-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}