{"product_id":"1mrk000173-ber05-abb-binary-i-o-module-relion-600-series","title":"1MRK000173-BER05 ABB Binary I\/O Module Relion 600 Series","description":"\u003cp\u003eThe \u003cb\u003eABB 1MRK000173-BER05\u003c\/b\u003e, also cataloged as the \u003cb\u003e1MRK000173-BER05\u003c\/b\u003e Binary I\/O Module, operates as a dedicated hardware component for binary status acquisition and control trip command execution within \u003cb\u003eRelion 600\u003c\/b\u003e subrack protection systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Designation \u0026amp; Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e1MRK000173-BER05\u003c\/b\u003e: Full catalog part number specifying board layout and voltage threshold ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBER05\u003c\/b\u003e: Hardware variant designating 16 binary inputs paired with 10 binary relay outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRelion 600 Series\u003c\/b\u003e: Target protection and control IED platform chassis architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1MRK000173-BER05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBinary I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16x Binary Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10x Binary Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContact Rating (Outputs)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A @ 250 VAC \/ 30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage Ranges\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 \/ 48 \/ 110 \/ 125 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Threshold (ON)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 70% of rated voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 kV AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSlot-compatible with Relion 600 bays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 93% RH (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.3 x 17 x 1.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSubrack Interface \u0026amp; Internal Communication\u003c\/h3\u003e\n\u003cp\u003eThe card interfaces directly with the main chassis via the internal bus, maintaining backplane bus communication velocity for rapid event logging. Embedded logic circuits enable systematic I\/O density scaling across empty card slots, while onboard memory routines enforce firmware flash compatibility checks with the master central processing unit prior to operation.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1x ABB 1MRK000173-BER05 Binary I\/O Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1x Conductive anti-static protective enclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines \u0026amp; Wiring Standards\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eChassis Slot Insertion\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the card edges with the designated Relion 600 bay guide rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlide the board smoothly inward until the rear multi-pin connector seats firmly into the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the top and bottom panel captive screws to 0.5 Nm torque to establish chassis grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eTerminal Connections and Shielding\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eConnect input and output wiring via dedicated terminal blocks using copper conductors up to 2.5 mm2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure all field signal cable shields are clamped to the panel earth bar at the point of cabinet entry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum separation distance of 200 mm between binary signal conductors and high-voltage AC current transformer secondary circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat is the ON-state voltage threshold for the binary inputs?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA logical ON state is registered when the applied input signal exceeds 70% of the nominal rated DC voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat are the maximum continuous voltage and current limits for the output relay contacts?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe output contacts are rated for a maximum continuous switching capacity of 5 A at 250 VAC or 30 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eIs the 1MRK000173-BER05 module hot-swappable during operation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNo. System power to the Relion 600 enclosure must be de-energized prior to removing or inserting the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat level of electrical isolation is provided between channels and internal logic?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features a dielectric galvanic isolation rating of 2.5 kV AC between field circuitry and backplane electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat nominal DC voltage levels are compatible with the binary inputs?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe binary input channels support standard control voltages of 24 VDC, 48 VDC, 110 VDC, and 125 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHow fast does the module execute input state changes and output commands?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe total response time for state detection and output activation executes within less than 10 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHow does the unit maintain electrical ground continuity with the rack?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eGrounding is maintained through the metallic front panel plate and captive mounting screws locked to the subrack frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat happens if a firmware revision mismatch occurs during replacement?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe host CPU executes firmware flash compatibility routines during startup to block incompatible board initialization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021073305773,"sku":"1MRK000173-BER05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_1mrk000173-ber03_3_a241c7c6-d639-436f-9748-01cab439fbc4.jpg?v=1787893292","url":"https:\/\/www.maxwellplc.com\/products\/1mrk000173-ber05-abb-binary-i-o-module-relion-600-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}