{"product_id":"1794-tb3g-allen-bradley-terminal-bases-flex-i-o-series","title":"1794-TB3G Allen-Bradley Terminal Bases FLEX I\/O Series","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1794-TB3G\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1794-TB3G\u003c\/strong\u003e Terminal Bases, operates as a dedicated hardware component for signal processing or control execution within industrial automation architectures. This specific termination variant establishes the physical wire-to-bus connections necessary for modular distributed input and output systems, facilitating clear electrical paths between external field instruments and central monitoring hardware.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1794\u003c\/strong\u003e: Core catalog prefix designating the modular industrial FLEX I\/O platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-TB3G\u003c\/strong\u003e: Suffix code indicating a grounded terminal base layout containing 36 input\/output termination clamps, 2 common terminals, and 2 positive voltage source connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/A\u003c\/strong\u003e: Manufacturing series designation specifying the primary internal hardware architectural revision layer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-TB3G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.6 x 9.6 x 5.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution mechanism (actual loop draw managed by plugged module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Terminals\u003c\/td\u003e\n\u003ctd\u003e36 screw-clamp points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Terminals\u003c\/td\u003e\n\u003ctd\u003e2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Terminals\u003c\/td\u003e\n\u003ctd\u003e2 points (+V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Configuration\u003c\/td\u003e\n\u003ctd\u003eIntegrated chassis grounding terminal tracks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 open style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eDirect 35 mm DIN rail installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1794-TB3G\/A, 96269675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eThe structural interface of the base layout sustains local backplane communication across adjacent processing modules. By handling physical termination constraints within an open-style footprint, the framework supports a high I\/O density configuration across deterministic local area architectures. System configurations operating over Profinet or EtherNet\/IP networks utilize the copper connections inside the base to pass binary and analog register data packages without experiencing signal attenuation or communication bus speed degradation. Furthermore, strict physical tolerance manufacturing guarantees long-term hardware and firmware compatibility parameters whenever matching modular industrial processing devices are hot-swapped or upgraded during normal system lifecycle maintenance.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1794-TB3G FLEX I\/O Grounded Terminal Base Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Factory-installed FlexBus slide-to-lock interconnection block\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation parameters summary sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eGrounding Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit directly onto a zinc-plated, clear-chromate steel 35 mm DIN rail to establish a low-impedance path to frame ground.\u003c\/li\u003e\n\u003cli\u003eAvoid using non-conductive, painted, or heavily oxidized mounting rails that could prevent the grounding foot from making clean electrical contact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring Constraints\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStrip conductor insulation layers to exactly 7 mm before feeding the wire into the open terminal throat.\u003c\/li\u003e\n\u003cli\u003eTighten all active screw clamps to a target torque specification of 0.8 N.m to prevent loose compression connections.\u003c\/li\u003e\n\u003cli\u003eKeep signal wiring separation zones clear from multi-phase electrical motor circuits or arc-producing inductive elements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShielding Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTerminate field instrument shield drains directly at an isolated external system grounding bar located within the central control cubicle.\u003c\/li\u003e\n\u003cli\u003eDo not layer or connect field instrument shields to the common or voltage rails located on the base block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackplane Insertion Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the adjacent left-hand slot FlexBus connector interface is pushed in fully before snapping the terminal base down.\u003c\/li\u003e\n\u003cli\u003eDo not force module insertion pins onto the base socket alignment tracks; inspect for bent components before complete mating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Limitations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that ambient ambient temperatures inside the cabinet structure stay within the standard 0 to +55 deg C operational limits.\u003c\/li\u003e\n\u003cli\u003eMaintain clear space margins around all ventilation pathways to allow heat to rise naturally from active terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the hot-swap behavior when replacing a faulty I\/O module sitting on this terminal base?\u003c\/p\u003e\n\u003cp\u003eA: The terminal base maintains uninterrupted backplane communication continuity along the remaining FlexBus path, letting you hot-swap the attached active module under live system power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this base unit place any measurable backplane load on the system power supply?\u003c\/p\u003e\n\u003cp\u003eA: No, the hardware consists of passive conductor links, copper pathways, and terminal screws, meaning it draws 0 mA of local current from the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What redundancy switching delay is caused by this terminal base component during a processor changeover?\u003c\/p\u003e\n\u003cp\u003eA: The unit features no active electronic components, microprocessors, or registers, meaning it introduces a 0 ms switching delay during redundancy system swap sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are there internal firmware compatibility checks needed when swapping an older module onto a new revision base?\u003c\/p\u003e\n\u003cp\u003eA: No, the component is completely analog and structural, which renders it independent of system firmware flash levels, software builds, or module program revisions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the internal signal isolation mechanism operate within the terminal block layout?\u003c\/p\u003e\n\u003cp\u003eA: The hardware provides passive physical channels; all galvanic, optical, or channel-to-channel signal isolation operations are handled entirely by the active plugged I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What specific field wiring constraints govern the selection of conductors for these screw clamps?\u003c\/p\u003e\n\u003cp\u003eA: Use solid or stranded copper wire sized between 0.34 mm2 (22 AWG) and 2.1 mm2 (14 AWG) rated for the specific loop voltage levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What causes an unexpected ground loop fault across the 2 common terminals?\u003c\/p\u003e\n\u003cp\u003eA: Ground loops typically happen if external field device commons are tied to separate earth points while simultaneously landing on the base terminal rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this open-style IP20 housing be installed directly inside an outdoor washdown environment?\u003c\/p\u003e\n\u003cp\u003eA: No, it is rated IP20 open style, requiring installation inside an appropriately certified NEMA or IP-rated protective industrial cabinet to prevent dust and water intrusion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066459476141,"sku":"1794-TB3G","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1794-TB3G_23.jpg?v=1784025240","url":"https:\/\/www.maxwellplc.com\/products\/1794-tb3g-allen-bradley-terminal-bases-flex-i-o-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}