{"product_id":"1783-mms10-allen-bradley-stratix-5800-managed-ethernet-switch","title":"1783-MMS10 Allen-Bradley Stratix 5800 Managed Ethernet Switch","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1783-MMS10\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1783-MMS10\u003c\/strong\u003e Managed Ethernet Switch, operates as a dedicated hardware component for industrial Ethernet packet switching and dynamic network traffic management within EtherNet\/IP Network architectures.\u003c\/p\u003e\n\u003ch3\u003eProduct Matrix and Identifier Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1783\u003c\/strong\u003e: Allen-Bradley Stratix industrial networking platform identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMMS\u003c\/strong\u003e: Modular managed switch base hardware configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: Total embedded port capability supporting up to 10 network connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModule Hardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1783-MMS10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 cm x 11.5 cm x 13.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e30 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Input Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 48 VDC redundant dual inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Ethernet Ports\u003c\/td\u003e\n\u003ctd\u003e10 ports (6 x 10\/100\/1000Base-T RJ45 + 4 x 100\/1000Base-X SFP combo slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP30 industrial enclosure rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Operations and Firmware Integrity\u003c\/h3\u003e\n\u003cp\u003eThe switch leverages integrated EtherNet\/IP deterministic networks execution engines to maintain layer-2 prioritization for high-density I\/O traffic profiles. Internal firmware flash compatibility provides automated operating system image restoration and configuration file validation across hardware reboot events. Memory allocation guarantees predictable packet routing, minimal latency jitter, and continuous backplane bus communication velocity across modular expansion units.\u003c\/p\u003e\n\u003ch3\u003eModular Base Package Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1783-MMS10 Stratix 5800 Managed Switch Base\u003c\/li\u003e\n\u003cli\u003e1 x Dual-input Removable Power Supply Terminal Connector\u003c\/li\u003e\n\u003cli\u003e1 x Console Adapter Plug Assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Installation and Connection Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRail Attachment\u003c\/p\u003e\n\u003cp\u003eLatch the rear mounting spring bracket directly onto a standard 35 mm DIN rail until the bottom lock engages securely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrame Grounding\u003c\/p\u003e\n\u003cp\u003eRun a short, high-frequency 10 AWG copper ground strap from the enclosure earth screw directly to panel ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork Cabling\u003c\/p\u003e\n\u003cp\u003eUse shielded twisted-pair Cat 6 Ethernet cables and connect drain wires directly to metallic RJ45 port frames.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Terminal Wiring\u003c\/p\u003e\n\u003cp\u003eWire dual 12-48 VDC power channels to the removable terminal plug and torque terminal screws to 0.6 Nm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeat Clearance Space\u003c\/p\u003e\n\u003cp\u003eProvide a minimum physical gap clearance of 50 mm above and below the switch chassis to allow natural convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical port interface configuration is provided on the base 1783-MMS10 switch?\u003c\/p\u003e\n\u003cp\u003eThe base unit provides 10 fixed ports, comprising 6 copper RJ45 10\/100\/1000Base-T ports and 4 Gigabit SFP slot interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage range is supported for the main DC power connection?\u003c\/p\u003e\n\u003cp\u003eThe internal power supply circuit accepts nominal DC inputs spanning from 12 VDC to 48 VDC across redundant terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan optional expansion I\/O modules be hot-swapped while the base unit is running?\u003c\/p\u003e\n\u003cp\u003eExpansion modules attached to the side expansion connector require system power isolation prior to physical connection or removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient operating temperature envelope applies to cabinet installations?\u003c\/p\u003e\n\u003cp\u003eThe switch maintains standard rated operational performance within an ambient thermal window between -40 deg C and 60 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat network redundancy topologies are supported natively by the internal operating system?\u003c\/p\u003e\n\u003cp\u003eThe switch natively supports Device Level Ring (DLR), Resilient Ethernet Protocol (REP), and Spanning Tree Protocols (STP\/RSTP\/MSTP).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum power consumption rating for the base hardware unit?\u003c\/p\u003e\n\u003cp\u003eUnder full network traffic load and active port execution, maximum power dissipation reaches a limit of 30 W.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is local maintenance access achieved for diagnostic switch setup?\u003c\/p\u003e\n\u003cp\u003eDirect local diagnostics and command-line maintenance are accessed using the dedicated front console interface port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ingress protection level does the metal chassis housing provide?\u003c\/p\u003e\n\u003cp\u003eThe unit features an IP30 rated open-style metal enclosure designed for installation inside suitable control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47240340865197,"sku":"1783-MMS10","price":1880.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley_1783-mms10_1.jpg?v=1787029674","url":"https:\/\/www.maxwellplc.com\/products\/1783-mms10-allen-bradley-stratix-5800-managed-ethernet-switch","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}