{"product_id":"1783-bms10cl-allen-bradley-stratix-5700-managed-ethernet-switch","title":"1783-BMS10CL Allen-Bradley Stratix 5700 Managed Ethernet Switch","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1783-BMS10CL\u003c\/strong\u003e (\u003cstrong\u003e1783BMS10CL\u003c\/strong\u003e Stratix 5700 Managed Ethernet Switch) provides managed Ethernet connectivity through eight RJ45 ports and two combo ports, with a 12 to 48 VDC input range.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe supplied product information identifies 1783-BMS10CL as a Stratix 5700 managed Ethernet switch. The source also labels it as FLEX I\/O, but the stated product parameters identify the hardware as a Stratix 5700 switch. The FLEX I\/O designation is therefore not treated as the product series.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1783-BMS10CL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Model\u003c\/td\u003e\n\u003ctd\u003e1783BMS10CL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eStratix 5700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eManaged Ethernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Ports\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Ports\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo Ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card\u003c\/td\u003e\n\u003ctd\u003e1784-SD1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e19.5 x 19 x 24.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet Network Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 1783-BMS10CL is specified as a managed Ethernet switch within the Allen-Bradley Stratix 5700 platform. Its 10-port configuration consists of eight RJ45 ports and two combo ports.\u003c\/p\u003e\n\u003cp\u003eThe available data confirms a 12 to 48 VDC input supply and compatibility with the 1784-SD1 memory card. Specific Ethernet data rates, switching capacity, VLAN limits, firmware revisions, and supported redundancy protocols are not provided and are therefore not assigned here.\u003c\/p\u003e\n\u003cp\u003eFor EtherNet\/IP systems, network topology and configuration should be established according to the installed Stratix 5700 system documentation. Deterministic network behavior depends on the complete network architecture rather than the switch catalog number alone.\u003c\/p\u003e\n\u003ch3\u003eMemory and Configuration Interface\u003c\/h3\u003e\n\u003cp\u003eThe supplied specification identifies the 1784-SD1 as the applicable memory card. No detailed memory capacity, supported file structure, configuration transfer procedure, or firmware storage function is provided in the supplied data.\u003c\/p\u003e\n\u003cp\u003eFirmware compatibility should be checked against the exact switch revision and installed system software before configuration changes or replacement.\u003c\/p\u003e\n\u003ch3\u003eOrdering Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1783-BMS10CL Stratix 5700 Managed Ethernet Switch\u003c\/li\u003e\n\u003cli\u003eCatalog reference: 1783BMS10CL\u003c\/li\u003e\n\u003cli\u003e8 x RJ45 Ethernet ports\u003c\/li\u003e\n\u003cli\u003e2 x combo ports\u003c\/li\u003e\n\u003cli\u003e1 x compatible 1784-SD1 memory card when separately specified\u003c\/li\u003e\n\u003cli\u003eEthernet cables, power supply, mounting hardware, and memory card are not confirmed as included unless specifically listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePower Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the available DC supply is within the specified 12 to 48 VDC input range.\u003c\/li\u003e\n\u003cli\u003eUse appropriately rated control wiring for the installed DC supply.\u003c\/li\u003e\n\u003cli\u003eKeep DC power wiring separated from high-current motor and switching circuits where practical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect RJ45 network cables according to the configured Ethernet topology.\u003c\/li\u003e\n\u003cli\u003eAvoid routing communication cables directly alongside high-voltage conductors for extended distances.\u003c\/li\u003e\n\u003cli\u003eProtect connectors from excessive mechanical tension and vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the switch on the designated mounting surface using the applicable hardware.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient clearance around the enclosure for cable access and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eDo not obstruct ventilation openings where present.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration and Firmware\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRecord the existing switch configuration before replacement.\u003c\/li\u003e\n\u003cli\u003eVerify firmware compatibility before transferring configuration files.\u003c\/li\u003e\n\u003cli\u003eDo not remove or insert the 1784-SD1 memory card while the equipment is energized unless the applicable installation documentation explicitly permits the operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat series does the 1783-BMS10CL belong to?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied product parameters identify it as an Allen-Bradley Stratix 5700 managed Ethernet switch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many Ethernet ports are provided?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified configuration contains 10 ports: 8 RJ45 ports and 2 combo ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat DC input voltage is specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe listed input voltage range is 12 to 48 VDC. The actual system supply should remain within this specified range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the switch use a memory card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied information identifies the 1784-SD1 as the applicable memory card. Capacity and configuration functions are not specified in the provided data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs power consumption specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo power consumption value is provided in the supplied specifications. A system power calculation should therefore use the applicable manufacturer documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the switch hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHot-swap capability is not established by the supplied data. Installation or replacement should follow the applicable Stratix 5700 procedure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating temperature is specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo operating temperature range is provided. Environmental suitability should be confirmed using the technical documentation for the exact hardware revision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Ethernet protocol performance is confirmed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied data confirms a managed Ethernet switch, but does not specify switching throughput, VLAN capacity, EtherNet\/IP features, or redundancy timing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066448826541,"sku":"1783-BMS10CL","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley_1783-bms10cl.jpg?v=1786541309","url":"https:\/\/www.maxwellplc.com\/products\/1783-bms10cl-allen-bradley-stratix-5700-managed-ethernet-switch","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}