{"product_id":"1769-l33er-allen-bradley-programmable-controller-compactlogix-cpu-processors","title":"1769-L33ER Allen-Bradley Programmable Controller CompactLogix CPU Processors","description":"\u003cp\u003eConfigured for high-speed logic execution in distributed control networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1769-L33ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1769L33ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable Automation Controller) provides direct physical and electrical execution of motion control commands and industrial I\/O data processing.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix and Designator\u003c\/h3\u003e\n\u003cp\u003eThe 1769-L33ER is a modular controller with 2 MB of user memory. The \"ER\" suffix denotes integrated dual-port EtherNet\/IP connectivity supporting Device Level Ring (DLR) topologies. This model supports up to 32 expansion I\/O modules across 3 banks, with an included SD card slot for non-volatile data storage.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1769-L33ER\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 x 17 x 9.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Ethernet\/IP, 1 x USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe 1769-L33ER utilizes deterministic EtherNet\/IP networks to facilitate motion control and high-speed I\/O status updates. Firmware flash compatibility is governed by the system project requirements, ensuring that backplane bus communication velocity remains synchronized with the controller scan cycle. Users must verify I\/O density scaling limits when connecting modules across the 3-bank architecture.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 1769-L33ER Controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 1 GB Secure Digital (SD) Card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 1769-ECR End Cap (Right side).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Programming software, Ethernet cabling, and external power supplies are supplied as separate catalog items.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Secure the controller onto a standard 35 mm DIN rail. Ensure the power supply is installed to the left of the controller, and expansion modules are connected to the right.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTermination: Always attach the 1769-ECR (Right End Cap) to the final module in the bank to complete the backplane communication circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Connect the chassis ground to a dedicated earth bus using a 2.5 mm squared conductor to mitigate high-frequency electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration: Set the front toggle switch to PROG (Program) mode during the initial commissioning phase to prevent unauthorized execution of logic before verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Dispatch\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipment via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll units are secured in anti-static industrial packaging to prevent electrostatic discharge and mechanical impact during international transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Technical Queries\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the unit support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1769-L33ER does not support hot-swapping. All power must be removed from the chassis backplane before inserting or removing the controller or any connected I\/O modules. Live insertion will cause transient surges that damage internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the SD card used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1 GB SD card is for non-volatile storage, firmware recovery, and project backup. It can support up to 2 GB cards. The controller will use the card for automatic data logging if configured within the programming software environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the network topology limits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe dual Ethernet ports support DLR (Device Level Ring) topologies, which provide media redundancy. When using DLR, ensure the supervisor node is correctly identified to prevent network loops and broadcast storms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is firmware compatibility managed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirmware must be flashed to the specific version required by the project file. Mismatched firmware versions will cause the controller to enter a fault state. Always verify versions via the software tool before initiation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum I\/O capacity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller supports up to 32 I\/O modules distributed across 3 banks. Exceeding this count or the physical power budget of the backplane will result in communication errors and potential power supply failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the USB port be used for permanent control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe USB port is designed strictly for temporary local programming and diagnostic tasks. It is not shielded for permanent industrial control connections and should not be used as a primary communication interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is memory partitioned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2 MB memory is allocated between user logic, communication buffers, and data tags. Memory usage must be monitored during online edits; exceeding the limit will prevent the application from running.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes scan time drift?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eScan time drift is typically caused by high-priority tasks or excessive network traffic. Ensure the number of Ethernet nodes is within the 32-node limit and optimize logic code to minimize task execution duration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066432540845,"sku":"1769-L33ER","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1769-L33ER-1.jpg?v=1780311158","url":"https:\/\/www.maxwellplc.com\/products\/1769-l33er-allen-bradley-programmable-controller-compactlogix-cpu-processors","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}