{"product_id":"1769-l31-allen-bradley-dual-serial-port-controller-compactlogix-cpu-processors","title":"1769-L31 Allen-Bradley Dual Serial Port Controller CompactLogix CPU Processors","description":"\u003cp\u003eConfigured for serial-based process communication and logic execution, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1769-L31\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1769-L31\/A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcessor) provides direct physical and electrical execution of DF1\/ASCII data transfer and controller I\/O management.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 1769-L31 controller features 512 KB of user memory and dual serial ports. The module designator \"A\" indicates the hardware revision level. This processor is engineered for small-scale automation applications requiring legacy serial protocol support without integrated Ethernet interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1769-L31\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.7 x 12.7 x 10.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.61 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 KB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x RS-232 Serial Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe module supports backplane bus communication velocity settings optimized for the 1769 Compact I\/O family. Firmware flash compatibility is strictly managed; technicians must utilize the appropriate configuration software to ensure that I\/O density scaling—up to 16 modules across 3 banks—stays within the backplane current limits of 330 mA at 5 VDC and 40 mA at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 1769-L31 CompactLogix Controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 1769-ECR End Cap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Programming cables and serial communication adapters are supplied as separate catalog items.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Secure the controller onto a standard 35 mm DIN rail or panel surface. Ensure sufficient clearance for airflow to maintain operating temperature within 0 to 60 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Connect the chassis ground to a low-impedance earth ground to prevent electromagnetic interference (EMI) on serial lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial Wiring: Follow Wiring Category 2 requirements for communication ports to prevent signal attenuation and data corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironment: Verify that relative humidity remains between 5% and 95% noncondensing to prevent internal circuit oxidation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistical Dispatch Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipment via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll units are protected by anti-static industrial packaging to ensure mechanical integrity and minimize electrostatic discharge risks during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Technical Queries\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the unit support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1769-L31 does not support hot-swapping. All power must be disconnected from the chassis backplane before inserting or removing the processor. Live insertion will cause transient voltage spikes that permanently damage the backplane pins and the internal controller circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the RS-232 port configured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe two RS-232 ports offer different electrical characteristics: one is isolated (DF1\/ASCII) and the other is non-isolated (DF1 only). Users must select the correct port based on the required galvanic isolation level and the specific communication protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is firmware flash managed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirmware updates must be performed via the serial ports using the vendor configuration software. A stable power supply is necessary; power loss during the flash operation will corrupt the bootloader, resulting in a non-recoverable processor failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the limitations of I\/O scaling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe processor supports up to 16 I\/O modules across 3 physical banks. Exceeding these limits or the total backplane current capacity (330 mA at 5 VDC) will induce communication faults and destabilize the local bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes serial communication drift?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCommunication errors are often attributed to poor cable shielding or ground loops. Ensure that the RS-232 serial cables are properly shielded and grounded at one end. Excessive cable lengths should be avoided to prevent signal distortion and parity errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the memory capacity expandable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 512 KB user memory is fixed on the 1769-L31 module. If the application requirements exceed this memory size, the controller must be upgraded to a model with higher capacity to avoid \"out of memory\" faults during runtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the mode switch used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe front-mounted toggle switch controls the processor operating mode. Set the switch to \"PROG\" during initial configuration and firmware updates. Setting it to \"RUN\" locks the memory for normal operation and prevents online edits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the storage temperature limit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device can be stored at temperatures between -40 and 85 deg C. Exceeding these limits can compromise the integrity of the internal capacitors and the reliability of the memory retention circuitry during long-term storage periods.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066431623341,"sku":"1769-L31","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1769-L31-5.jpg?v=1780474926","url":"https:\/\/www.maxwellplc.com\/products\/1769-l31-allen-bradley-dual-serial-port-controller-compactlogix-cpu-processors","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}