{"product_id":"1769-iq32t-allen-bradley-compactlogix-digital-input-module","title":"1769-IQ32T Allen-Bradley CompactLogix Digital Input Module","description":"\u003cp\u003eConfigured for discrete signal acquisition in CompactLogix backplane-based control systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1769-IQ32T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1769-IQ32T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module) provides direct electrical termination of 32 point DC sink\/source input channels operating at 24 VDC levels. The module executes signal state latching and deterministic cyclic data transfer across the backplane bus to the controller, maintaining synchronized mapping of field device status.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1769-IQ32T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.0 x 14.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 mA at 5.1 VDC (Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Point DC Sink\/Source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Backplane Communication and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 1769-IQ32T utilizes high-speed backplane bus communication to ensure deterministic data throughput within the CompactLogix controller scan cycle. Through I\/O density scaling, the 32-channel configuration optimizes rack space by aggregating multiple discrete signals into a single physical slot while maintaining sub-millisecond state update resolution. The module architecture incorporates firmware-defined cyclic communication, which ensures that input state transitions are captured at the hardware level prior to the controller task scan, mitigating sampling jitter and transient signal distortion.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the module is installed on a 1769 series chassis with all power removed. Align the tongue-and-groove connectors to ensure correct bus alignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Polarity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen configuring for sink or source operation, verify the external 24 VDC supply polarity matches the required common configuration for the specific input group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn high EMI environments, utilize shielded twisted-pair cabling for field inputs. Ground the shield at the source end only to prevent ground loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Separation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain physical separation between discrete input wiring and high-voltage AC or inductive load power conductors to minimize crosstalk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure terminal block connections to manufacturer-specified torque limits. Ensure firm seating on the backplane connector to prevent bus communication interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1769-IQ32T support hot-swap insertion within the CompactLogix chassis?\u003c\/p\u003e\n\u003cp\u003eA: No, hot-swap is not supported. The controller must be powered down prior to module installation or removal to prevent electrical damage to the backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: Is individual channel-to-channel isolation provided?\u003c\/p\u003e\n\u003cp\u003eA: No, the input channels are grouped electrically. Individual point-level isolation is not implemented.\u003c\/p\u003e\n\u003cp\u003eQ: Are the input channels configurable for mixed sink and source wiring simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Yes, channels support sink or source logic depending on the field device wiring reference scheme applied to the common terminals.\u003c\/p\u003e\n\u003cp\u003eQ: How is the input state refresh coordinated with the controller?\u003c\/p\u003e\n\u003cp\u003eA: Input states are latched at the module hardware level and transmitted via the backplane bus using a deterministic cyclic scan synchronized with the controller's task execution cycle.\u003c\/p\u003e\n\u003cp\u003eQ: Is the firmware on the 1769-IQ32T field programmable?\u003c\/p\u003e\n\u003cp\u003eA: No, the module utilizes preloaded base logic. Firmware updates are not supported at the user level for this specific hardware revision.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066430738605,"sku":"1769-IQ32T","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1769-IQ32T-1.jpg?v=1780456802","url":"https:\/\/www.maxwellplc.com\/products\/1769-iq32t-allen-bradley-compactlogix-digital-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}