{"product_id":"1769-ascii-allen-bradley-ascii-interface-module-compactlogix","title":"1769-ASCII Allen-Bradley ASCII Interface Module CompactLogix","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1769-ASCII\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1769-ASCII\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eASCII Interface Module utilized to execute serial communication and data parsing across CompactLogix platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1769-ASCII\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.3 cm x 8.7 cm x 3.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to backplane power budget\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSerial Interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232, RS-422, RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDuplex Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull (RS-232), Half (RS-422\/RS-485)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control System Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1769-ASCII module is engineered to provide deterministic serial data handling within the CompactLogix architecture. It utilizes backplane bus communication to interface with the processor, allowing for I\/O density scaling across the local controller rack. Firmware flash compatibility ensures that the communication drivers can be updated to accommodate specific serial protocol requirements or system revisions. The module provides the necessary isolation and signal conditioning to facilitate reliable serial data transfer in environments where electromagnetic noise is present.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module is designed for mounting on a 35 mm DIN rail or directly onto a panel surface. Ensure the power is disconnected from the backplane before mounting or removing the module to prevent electrical damage. For serial communication, verify the wiring configuration matches the selected mode: full duplex for RS-232 and half duplex for RS-422\/RS-485. Shielded cables are required for all serial connections to mitigate noise interference; the cable shield should be terminated at a single common earth point to prevent ground loops. Maintain adequate clearance around the module to allow for natural convection cooling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1769-ASCII module support Removal and Insertion Under Power (RIUP)?\u003c\/p\u003e\n\u003cp\u003eA: No. RIUP is not supported for this module. The system must be de-energized prior to removing or installing the module to avoid damage to the backplane communication pins.\u003c\/p\u003e\n\u003cp\u003eQ: Can the two channels be configured for different protocols simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each channel is independent and can be configured individually for the supported serial interface types (RS-232, RS-422, or RS-485) depending on the field device requirements.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle communication buffers?\u003c\/p\u003e\n\u003cp\u003eA: The module manages incoming and outgoing ASCII strings through internal buffers; application logic in the CPU is required to read and clear these buffers to prevent data overflows.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power required for the serial interface?\u003c\/p\u003e\n\u003cp\u003eA: No. The serial interface ports are powered by the module's internal circuitry, which draws its power from the CompactLogix backplane.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066429329581,"sku":"1769-ASCII","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1769-ASCII_1.jpg?v=1780469764","url":"https:\/\/www.maxwellplc.com\/products\/1769-ascii-allen-bradley-ascii-interface-module-compactlogix","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}