{"product_id":"1761-net-dni-allen-bradley-communication-adaptor-micrologix","title":"1761-NET-DNI Allen-Bradley Communication Adaptor MicroLogix","description":"\u003cp\u003eConfigured for DF1 full-duplex to DeviceNet protocol conversion in industrial control networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1761-NET-DNI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e1761NETDNI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Adaptor) provides direct physical\/electrical bridge execution between serial-based PLCs and DeviceNet fieldbus architectures.\u003c\/p\u003e\n\u003ch3\u003eProduct Designation and Nomenclature\u003c\/h3\u003e\n\u003cp\u003eThe 1761-NET-DNI serves as a gateway device. It maps DF1 protocol frames to DeviceNet object models, allowing legacy MicroLogix and SLC controllers to participate in broader networked automation schemes without requiring native fieldbus capability on the controller itself.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1761-NET-DNI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.18 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 x 6.3 x 12.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 W (typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (+\/- 10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-95% RH (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNetwork Determinism and Protocol Conversion\u003c\/h3\u003e\n\u003cp\u003eThe module facilitates integration into EtherNet\/IP and DeviceNet deterministic networks. It manages serial data encapsulation with minimal latency, ensuring that PLC I\/O status updates and messaging requests remain within the required deterministic time windows. Firmware compatibility should be validated against the connected controller's RSLogix\/Studio 5000 project file to ensure proper data packet alignment and prevent timing synchronization faults during high-density I\/O traffic.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAllen-Bradley 1761-NET-DNI communication module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeviceNet connector (field-terminable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Serial interconnect cables (such as 1761-CBL-PM02) are not included and must be sourced per specific controller port requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePhysical Placement: Mount horizontally on a standard DIN-rail to ensure adequate convective cooling within the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Connect the module chassis ground terminal directly to the enclosure bus bar using a low-impedance copper strap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the DeviceNet cable shield is terminated at the designated ground point to mitigate signal noise and ensure compliance with electromagnetic compatibility standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Maintain a minimum of 100 mm separation between communication cabling and high-voltage AC power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal Logistics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipment via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll modules are protected by anti-static industrial packaging to prevent discharge damage and ensure integrity during international transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module operate in hazardous environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1761-NET-DNI is intended for standard industrial control panels and does not carry intrinsic safety (Ex i) ratings for direct installation in hazardous zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the health status of the module monitored?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInternal status is indicated via front-panel LEDs, which report module power, communication activity, and DeviceNet network state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes communication timeouts with this adaptor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTimeouts are typically caused by baud rate mismatches between the DF1 serial port and the PLC, or incorrect DeviceNet node address (MAC ID) assignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the firmware field-upgradeable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module supports firmware updates via the serial port using standard Allen-Bradley configuration utilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the expected service life?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnder specified operating temperatures (0 to 55 deg C) and non-condensing humidity levels, the hardware is designed for long-term continuous operation within standard industrial duty cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066423333037,"sku":"1761-NET-DNI","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1761-NET-DNI-1.jpg?v=1780649030","url":"https:\/\/www.maxwellplc.com\/products\/1761-net-dni-allen-bradley-communication-adaptor-micrologix","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}