{"product_id":"1756-oa16-allen-bradley-controllogix-16-point-ac-digital-output-module","title":"1756-OA16 Allen-Bradley ControlLogix 16-Point AC Digital Output Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Allen-Bradley 1756-OA16 is a high-density discrete output module designed for the ControlLogix® platform,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding 16 independent channels for switching AC loads.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOperating within a broad voltage spectrum of 74V to 265V AC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module is an ideal interface for controlling industrial actuators,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emotor starters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand indicators.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt features two isolated groups of eight points each,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for flexible wiring configurations across different power phases or circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eEngineered for the 1756 chassis system,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 1756-OA16 facilitates seamless communication between the controller and field devices.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt utilizes Triac-based switching to handle inductive and resistive loads with precision.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module includes sophisticated onboard diagnostics,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as \"Fuse Blown\" and \"Field Power Loss\" detection,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich report directly to the controller tags to minimize troubleshooting time and protect the hardware from overcurrent conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Performance and Diagnostic Capabilities\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 1756-OA16 is built to maintain system integrity in rigorous manufacturing environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt supports \"Remove and Insert Under Power\" (RIUP) functionality,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing technicians to replace modules without powering down the entire chassis.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor wiring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module utilizes Removable Terminal Blocks (RTB),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003especifically the 1756-TBNH or 1756-TBSH,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich simplify maintenance by allowing the wiring harness to remain intact during module swaps.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eTo ensure operational safety,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module offers configurable failure states.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUsers can program each point to go \"Off,\u003c\/span\u003e\u003cspan class=\"\"\u003e\" \"On,\u003c\/span\u003e\u003cspan class=\"\"\u003e\" or \"Hold Last State\" in the event of a controller communication loss.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWith a pilot duty rating of 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 A,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is robust enough for high-cycle applications while maintaining low power dissipation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe front panel features individual LED indicators for each of the 16 channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding immediate visual confirmation of output status and fault conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1756-OA16\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDiscrete AC (Triac)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 (8 points per group)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e74–265V AC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e47–63 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Current Rating:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 A max per point @ 60°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e2.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 A max per group @ 60°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e4.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 A max per module @ 60°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMinimum Load Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e10 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInrush Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5 A for 43 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBackplane Current:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e400 mA @ 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e1V DC; 2 mA @ 24V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e6.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Watts (Maximum)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e250V (Continuous),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBasic Insulation Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e14.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 x 3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e26 kg (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e57 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eCore Features and Application Benefits\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChannel Density:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 points in a single-slot format maximize I\/O capacity within limited chassis space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInductive Load Management:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePilot duty rated for reliable switching of valves and relays without external suppression in most cases.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eReal-time Diagnostics:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDetects blown fuses and loss of field power per group to prevent process errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRugged Construction:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for Class 1 Division 2 hazardous locations and tested for industrial-grade vibration and shock.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519099494573,"sku":"1756-OA16","price":1399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-1756-oa16-controllogix-discrete-output-module-ifigfjqqoj1.jpg?v=1766987102","url":"https:\/\/www.maxwellplc.com\/products\/1756-oa16-allen-bradley-controllogix-16-point-ac-digital-output-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}