{"product_id":"1746-ib32-c-allen-bradley-slc-500-32-point-dc-input-module","title":"1746-IB32\/C Allen-Bradley SLC 500 32 Point DC Input Module","description":"\u003cp\u003eConfigured for high-density multi-channel discrete DC signal acquisition in modular control chassis, the \u003cstrong\u003eAllen-Bradley 1746-IB32\/C\u003c\/strong\u003e (\u003cstrong\u003e1746-IB32\u003c\/strong\u003e) Digital Input Module provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform Series\u003c\/strong\u003e: Allen-Bradley SLC 500 modular rack controller infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Catalog Identifier\u003c\/strong\u003e: 1746-IB32 designating a 32-point digital DC sinking input configuration arranged in 8 points per common group.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Revision Suffix\u003c\/strong\u003e: Revision \/C indicating updated circuit board layouts and backward compatibility relative to baseline releases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-IB32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 x 13 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA at 5 V DC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 discrete sink load points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e15 to 30 V DC at 50 deg C \/ 15 to 26.4 V DC at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical channel-to-backplane isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Controller \u0026amp; Deterministic Integration\u003c\/h3\u003e\n\u003cp\u003eThe embedded hardware executes high-speed digital state acquisition by leveraging backplane bus communication velocity licences to maintain deterministic network synchronization across system racks. Firmware flash compatibility ensures seamless integration with modern configuration utilities, while dynamic I\/O density scaling supports expanded sensor topologies without introducing processing latencies.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1746-IB32\/C 32 Point DC Input Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable terminal block connector interface\u003c\/li\u003e\n\u003cli\u003e1 x Hardware documentation reference sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChassis Slot Placement: Insert the printed circuit board assembly firmly into any available I\/O slot of the SLC 500 chassis, ensuring proper alignment with backplane edge connectors before securing retaining mechanisms.\u003c\/li\u003e\n\u003cli\u003eSignal Wiring Segregation: Route all incoming DC field sensor lines away from high-voltage AC power conduits and motor drives to prevent electromagnetic coupling and spurious state switching.\u003c\/li\u003e\n\u003cli\u003eTerminal Torque Verification: Ensure all screw terminals on the removable block are torqued down securely on stripped copper conductors to prevent intermittent electrical contact during vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Engineering Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do the optical isolation barriers handle high-voltage DC transients on the 32 input lines?\u003c\/p\u003e\n\u003cp\u003eA: High-dielectric optocouplers provide complete galvanic separation between the external field wiring and the internal processor logic, preventing transient voltage spikes from reaching sensitive components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary electrical consequence of applying input voltages that exceed the maximum 30 V DC threshold?\u003c\/p\u003e\n\u003cp\u003eA: Overvoltage conditions beyond the rated limit can saturate the input filtering stages and cause thermal degradation of the internal limiting components, potentially destroying the optocoupler stage if sustained.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this module process high-frequency pulse trains from fast-acting encoders without signal distortion?\u003c\/p\u003e\n\u003cp\u003eA: No, this module is engineered for standard discrete status indication and low-frequency contact closures, meaning rapid pulse trains will experience filtering delays and state-skipping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the internal filtering network mitigate high-frequency electrical noise picked up by long field wiring runs?\u003c\/p\u003e\n\u003cp\u003eA: An RC low-pass filter network on each input channel attenuates high-frequency transients and switching noise before the signal reaches the optical isolation threshold detector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What occurs to the processor input data table if the module is extracted while the chassis power is active?\u003c\/p\u003e\n\u003cp\u003eA: Live extraction disrupts backplane communication on the local bus, causing the processor to register a rack fault and freeze or clear input image tables depending on configured fault routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is it critical to use shielded twisted-pair cables when routing low-level signals through noisy industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: Shielded cabling suppresses electromagnetic and radio frequency interference, ensuring that induced voltage spikes do not cross the logic-high threshold and trigger false inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does operating the module near the upper thermal limit of +60 deg C impact component lifespan?\u003c\/p\u003e\n\u003cp\u003eA: Continuous operation near the maximum temperature rating accelerates the thermal aging of electrolytic capacitors and semiconductor junctions, increasing long-term failure rates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What specific maintenance checks should be performed periodically on the removable terminal block?\u003c\/p\u003e\n\u003cp\u003eA: Technicians should inspect terminal screws for loosening caused by mechanical vibration and check for signs of oxidation or moisture ingress on exposed copper wire strands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066403934381,"sku":"1746-IB32","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1746-IB32_233.jpg?v=1785142523","url":"https:\/\/www.maxwellplc.com\/products\/1746-ib32-c-allen-bradley-slc-500-32-point-dc-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}