{"product_id":"1734-ssi-allen-bradley-ssi-module-point-i-o-series","title":"1734-SSI Allen-Bradley SSI Module POINT I\/O Series","description":"\u003cp\u003eConfigured for serial synchronous encoder data acquisition in POINT I\/O systems, the \u003cstrong\u003eAllen-Bradley 1734-SSI\u003c\/strong\u003e (\u003cstrong\u003e1734-SSI\u003c\/strong\u003e SSI Module) provides direct physical\/electrical execution through a single SSI communication channel.\u003c\/p\u003e\n\u003ch3\u003eModel Identification \u0026amp; Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 1734-SSI is a Serial Synchronous Interface module designed for Allen-Bradley POINT I\/O architecture. The module provides one SSI communication port for connecting SSI-compatible absolute position devices and transferring synchronous serial data through the POINTBus network.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1734-SSI\u003c\/td\u003e\n\u003ctd\u003eSerial Synchronous Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley POINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eSSI Serial Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSI Channels\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-SSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSSI Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 x 6 x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.94 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e110 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSI Channels\u003c\/td\u003e\n\u003ctd\u003e1 SSI port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eSerial Synchronous Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O modular mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and POINTBus Data Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1734-SSI operates as a POINT I\/O communication module within distributed I\/O systems. The module exchanges SSI device data through the POINTBus backplane while maintaining modular I\/O expansion capability.\u003c\/p\u003e\n\u003cp\u003eThe Allen-Bradley POINT I\/O platform uses deterministic industrial communication methods for controller integration. Module configuration parameters are stored through the controller software environment and depend on the selected network adapter and controller architecture.\u003c\/p\u003e\n\u003ch3\u003eFirmware and I\/O Configuration Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module configuration requires matching firmware compatibility between the POINT I\/O adapter, controller system, and installed I\/O modules. Firmware flash compatibility should be verified before replacing modules in an active control architecture.\u003c\/p\u003e\n\u003cp\u003eThe 1734-SSI supports I\/O density scaling through POINT I\/O modular installation, allowing additional modules to be added according to system architecture requirements.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe supplied configuration normally includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-SSI SSI Module\u003c\/li\u003e\n\u003cli\u003e1 x POINT I\/O module housing assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional components required for operation may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePOINT I\/O terminal base\u003c\/li\u003e\n\u003cli\u003eCompatible POINT I\/O adapter module\u003c\/li\u003e\n\u003cli\u003eController communication interface\u003c\/li\u003e\n\u003cli\u003eSSI field device wiring accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible POINT I\/O terminal base.\u003c\/li\u003e\n\u003cli\u003eConfirm module seating before applying system power.\u003c\/li\u003e\n\u003cli\u003eMaintain enclosure protection suitable for the installation environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSSI Signal Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse wiring suitable for serial synchronous communication signals.\u003c\/li\u003e\n\u003cli\u003eKeep SSI communication wiring separated from high voltage conductors.\u003c\/li\u003e\n\u003cli\u003eApply proper cable shielding and grounding practices where electrical interference exists.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSystem Commissioning\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVerify SSI device parameters before enabling data exchange.\u003c\/li\u003e\n\u003cli\u003eConfirm controller recognition of the module after installation.\u003c\/li\u003e\n\u003cli\u003eCheck communication status indicators during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat communication interface does the 1734-SSI support?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module supports Serial Synchronous Interface communication for SSI-compatible devices requiring synchronous serial data transfer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHow many SSI channels are available?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1734-SSI provides one dedicated SSI communication channel through the POINT I\/O module structure.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat supply voltage range is supported?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module operates with a supply voltage range of 10 to 28.8 VDC according to the provided technical specifications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the POINTBus current requirement?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module requires 110 mA of POINTBus current during operation within the POINT I\/O system.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the operating temperature range?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specified operating temperature range is -20 to 55 deg C for normal module operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan the module be installed without a POINT I\/O terminal base?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. The module requires a compatible POINT I\/O terminal base for mechanical mounting and electrical connection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDoes the module support multiple SSI devices simultaneously?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo. The hardware configuration provides one SSI communication port for a single SSI device connection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhat installation practices affect SSI signal quality?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProper shielding, grounding, cable routing, and separation from electrical noise sources affect SSI communication stability.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066401345709,"sku":"1734-SSI","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-SSI_1.jpg?v=1785124504","url":"https:\/\/www.maxwellplc.com\/products\/1734-ssi-allen-bradley-ssi-module-point-i-o-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}