{"product_id":"1734-oe2v-allen-bradley-point-i-o-series-analog-output-module","title":"1734-OE2V Allen-Bradley POINT I\/O Series Analog Output Module","description":"\u003cp\u003eConfigured for voltage signal generation in EtherNet\/IP based industrial control architectures, the \u003cstrong\u003eAllen-Bradley 1734-OE2V\u003c\/strong\u003e (\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e POINT I\/O Analog Output Module) provides direct digital-to-analog execution for field output devices.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1734-OE2V is a POINT I\/O analog output module providing two single-ended, non-isolated voltage outputs. The module converts controller data values into analog voltage signals for connected field devices.\u003c\/p\u003e\n\u003cp\u003eThe module supports 0 to 10 V output range, 14-bit resolution, signed integer data formatting, and a digital-to-analog conversion rate of 20 microseconds.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OE2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 5.5 x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e2 Single-Ended Non-Isolated Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Load\u003c\/td\u003e\n\u003ctd\u003e3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Type\u003c\/td\u003e\n\u003ctd\u003eDigital-to-Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Rate\u003c\/td\u003e\n\u003ctd\u003e20 microseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eSigned Integer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP and I\/O Scaling Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OE2V operates within the Allen-Bradley POINT I\/O platform and integrates into distributed I\/O architectures through compatible POINT I\/O communication adapters.\u003c\/p\u003e\n\u003cp\u003eThe module supports I\/O density scaling by allowing compact installation of analog output channels in remote control locations. Controller output data is transferred through the POINT I\/O communication interface and converted into proportional voltage signals.\u003c\/p\u003e\n\u003cp\u003eThe module architecture supports deterministic industrial networks such as EtherNet\/IP when installed with compatible POINT I\/O network adapters. Firmware compatibility and adapter configuration must match the installed control system requirements.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-OE2V POINT I\/O Analog Output Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional POINT I\/O components required for operation may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePOINT I\/O terminal base assembly\u003c\/li\u003e\n\u003cli\u003eCompatible POINT I\/O communication adapter\u003c\/li\u003e\n\u003cli\u003eController-side configuration software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eModule Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible POINT I\/O terminal base.\u003c\/li\u003e\n\u003cli\u003eVerify terminal base compatibility before applying power.\u003c\/li\u003e\n\u003cli\u003eConfirm correct module position within the POINT I\/O assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWiring Requirements\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect analog voltage outputs according to the field device requirements.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded wiring practices for analog signal circuits.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-current power conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConfiguration Setup\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfigure output range and scaling parameters in the controller software.\u003c\/li\u003e\n\u003cli\u003eVerify signed integer output values correspond with required field voltage levels.\u003c\/li\u003e\n\u003cli\u003eCheck channel status indicators during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFirmware and Communication Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OE2V uses the POINT I\/O modular architecture for distributed analog output control. Communication behavior depends on the installed POINT I\/O adapter and controller network configuration.\u003c\/p\u003e\n\u003cp\u003eThe module does not provide isolated outputs, therefore field wiring design must consider grounding methods and signal reference requirements. Proper configuration ensures correct conversion between controller data values and analog output voltage levels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow many analog outputs are available on the 1734-OE2V?\u003c\/p\u003e\n\u003cp\u003eThe module provides 2 single-ended, non-isolated analog voltage output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage range does this module support?\u003c\/p\u003e\n\u003cp\u003eThe module supports a 0 to 10 V analog output range for connected field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the output channel electrically isolated?\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-OE2V provides non-isolated single-ended voltage outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of conversion does the module perform?\u003c\/p\u003e\n\u003cp\u003eThe module performs digital-to-analog conversion from controller data values to voltage signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat data format is used by this module?\u003c\/p\u003e\n\u003cp\u003eThe module uses signed integer data formatting for analog output values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the module resolution?\u003c\/p\u003e\n\u003cp\u003eThe analog output resolution is 14 bits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module operate without a POINT I\/O terminal base?\u003c\/p\u003e\n\u003cp\u003eNo. The module requires installation on a compatible POINT I\/O terminal base assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat affects analog output signal accuracy?\u003c\/p\u003e\n\u003cp\u003eSignal wiring, grounding, controller scaling, and connected device characteristics affect output accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400755885,"sku":"1734-OE2V","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OE2V_1.jpg?v=1785123799","url":"https:\/\/www.maxwellplc.com\/products\/1734-oe2v-allen-bradley-point-i-o-series-analog-output-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}