{"product_id":"1734-ie2c-allen-bradley-point-i-o-2-point-analog-input-module-point-i-o","title":"1734-IE2C Allen-Bradley POINT I\/O 2 Point Analog Input Module POINT I\/O","description":"\u003cp\u003eConfigured for analog signal acquisition in industrial control networks, the \u003cstrong\u003eAllen-Bradley 1734-IE2C\u003c\/strong\u003e (\u003cstrong\u003e1734-IE2C\u003c\/strong\u003e POINT I\/O 2 Point Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Cataloging and Suffix Variants\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model Identifier: 1734-IE2C\u003c\/li\u003e\n\u003cli\u003eSpare Model Reference: 1734IE2C\u003c\/li\u003e\n\u003cli\u003eSeries Platform: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eHardware Module Class: 2-Point Analog Input Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IE2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 x 5.5 x 7.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.6 W @ 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e75 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2-Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Type\u003c\/td\u003e\n\u003ctd\u003eDelta Sigma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory Calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Overload Fault Protected\u003c\/td\u003e\n\u003ctd\u003e28.8 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eSigned Integer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 28.8 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% Full Scale @ 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane and Deterministic Network Parameters\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with backplane bus communication protocols within Allen-Bradley rack architectures. Firmware flash compatibility ensures alignment with contemporary controller revisions, allowing deterministic I\/O density scaling across distributed nodes. Backplane power draw is maintained at 75 mA from the 5 V DC bus, ensuring minimal thermal dissipation loads across high-density node assemblies.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-IE2C Analog Input Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Factory calibration documentation sheet\u003c\/li\u003e\n\u003cli\u003e1 x Mechanical keyswitch configuration guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Deployment Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Ensure secure physical attachment to standard 35 mm DIN rails within the designated enclosure.\u003c\/li\u003e\n\u003cli\u003eShielded Cabling: Terminate signal cable shields to designated chassis ground points to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eKeyswitch Setting: Verify the physical keyswitch position is set to 3 prior to module insertion.\u003c\/li\u003e\n\u003cli\u003eTerminal Powering: Ensure external loop power supplies remain within the 10 to 28.8 V DC range to prevent input circuit faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Inquiry and Verification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal current draw from the 5 V DC backplane?\u003c\/p\u003e\n\u003cp\u003eThe module draws 75 mA from the 5 V DC backplane bus during normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat data format is utilized for the acquired analog values?\u003c\/p\u003e\n\u003cp\u003eAnalog input values are processed and transmitted in a Signed Integer data format.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the factory-set absolute accuracy of the module?\u003c\/p\u003e\n\u003cp\u003eThe absolute accuracy is specified at 0.1% Full Scale at an ambient temperature of 25 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the configured keyswitch position for this hardware revision?\u003c\/p\u003e\n\u003cp\u003eThe physical keyswitch position for this module variant is set to 3.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many input channels are supported per physical module?\u003c\/p\u003e\n\u003cp\u003eThe module supports exactly 2-Point single-ended current input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total power dissipation rating at maximum voltage?\u003c\/p\u003e\n\u003cp\u003eThe power dissipation is rated at 0.6 W at 28.8 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of analog-to-digital conversion technique is employed?\u003c\/p\u003e\n\u003cp\u003eThe hardware utilizes a Delta Sigma conversion architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the default input step response time per channel?\u003c\/p\u003e\n\u003cp\u003eThe default input step response is 70 ms when the notch filter is set to 60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066399445165,"sku":"1734-IE2C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-IE2C_13.jpg?v=1784733379","url":"https:\/\/www.maxwellplc.com\/products\/1734-ie2c-allen-bradley-point-i-o-2-point-analog-input-module-point-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}