{"product_id":"1734-8cfgdlx-allen-bradley-dc-configurable-i-o-module-point-i-o-series","title":"1734-8CFGDLX Allen-Bradley DC Configurable I\/O Module POINT I\/O Series","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1734-8CFGDLX\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1734-8CFGDLX\u003c\/strong\u003e DC Configurable I\/O Module, operates as a dedicated hardware component for configurable digital signal acquisition and output execution within POINT I\/O system networks.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 1734-8CFGDLX is an 8-channel DC configurable I\/O module designed for installation within the Allen-Bradley POINT I\/O platform. The module supports configurable field-side channels for industrial digital signal processing through a DIN rail mounted distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-8CFGDLX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Configurable I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Channels\u003c\/td\u003e\n\u003ctd\u003e8 configurable channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e11 Volts DC minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2-5 milliamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 x 6 x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Platform\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O backplane communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Platform Integration\u003c\/h3\u003e\n\u003cp\u003eAllen-Bradley POINT I\/O modules are designed for distributed PLC architectures where remote I\/O density scaling and deterministic EtherNet\/IP network communication are required. The 1734-8CFGDLX connects through the POINT I\/O backplane assembly and exchanges process data with the controller through the configured network adapter.\u003c\/p\u003e\n\u003cp\u003eThe module configuration supports flexible channel assignment, allowing the I\/O density of a POINT I\/O station to be adjusted according to field device requirements. Firmware flash compatibility should be verified before installation to ensure alignment between the module revision and the controller environment.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-8CFGDLX DC Configurable I\/O Module\u003c\/li\u003e\n\u003cli\u003e1 x Factory-installed electronic assembly\u003c\/li\u003e\n\u003cli\u003ePOINT I\/O terminal base assembly is required separately if not already available\u003c\/li\u003e\n\u003cli\u003eNetwork adapter and power distribution accessories are ordered separately according to system architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible DIN rail with the correct POINT I\/O terminal base.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module for wiring access and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eVerify that the terminal base connection is fully seated before applying system power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm field voltage levels before connecting DC input circuits.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring separately from high-current power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the control cabinet grounding design.\u003c\/li\u003e\n\u003cli\u003eVerify module addressing and controller configuration before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat type of signals does the 1734-8CFGDLX process?\u003c\/strong\u003e\u003cbr\u003eThe module processes configurable DC digital field signals through its 8-channel I\/O interface within a POINT I\/O distributed control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the 1734-8CFGDLX compatible with POINT I\/O systems?\u003c\/strong\u003e\u003cbr\u003eYes. The module is designed specifically for installation within the Allen-Bradley POINT I\/O platform using compatible terminal bases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the module require a separate terminal base?\u003c\/strong\u003e\u003cbr\u003eYes. POINT I\/O modules typically require a compatible terminal base assembly for field wiring connection and mechanical mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the module be installed on a standard DIN rail?\u003c\/strong\u003e\u003cbr\u003eYes. The module uses DIN rail mounting as part of the POINT I\/O distributed I\/O installation method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range of this module?\u003c\/strong\u003e\u003cbr\u003eThe specified operating temperature range is -20 to 55 deg C for standard industrial installation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the minimum input voltage requirement?\u003c\/strong\u003e\u003cbr\u003eThe module requires a minimum input voltage of 11 Volts DC according to the provided technical specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the module support firmware updates?\u003c\/strong\u003e\u003cbr\u003eFirmware compatibility depends on the installed controller environment and POINT I\/O system revision. Verify revision requirements before updating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow should field wiring be installed?\u003c\/strong\u003e\u003cbr\u003eField wiring should follow industrial control practices, including proper grounding, signal separation, and protection against electrical noise sources.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066398920877,"sku":"1734-8CFGDLX","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-8CFGDLX_13.jpg?v=1784730778","url":"https:\/\/www.maxwellplc.com\/products\/1734-8cfgdlx-allen-bradley-dc-configurable-i-o-module-point-i-o-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}