{"product_id":"1701-15-bently-nevada-proximitor-input-monitor-1701-fieldmonitor","title":"1701\/15 Bently Nevada Proximitor Input Monitor 1701 FieldMonitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 1701\/15\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1701\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Input Monitor, operates as a dedicated hardware component for radial vibration and thrust position tracking within 1701 FieldMonitor platforms.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1701\/15\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.26 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.5 cm x 2 cm x 10.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 Watt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 independent monitoring channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC and +5 VDC supplied from 1701 Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1% of full-scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGap Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 20 mV over range of -1 to -23 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGap \/ Setpoint Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mV \/ 0.10 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSetpoint Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5% of full-scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlex Read\/Write Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;= 25 millisec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing relative humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBuffered Output Specs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 30 m (100 ft) cable length at 60 pF\/ft, non-isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 2-channel monitor card executes continuous digitization of incoming raw displacement waveforms. Precise eddy-current probe scaling protocols translate proximity sensor data loops into engineering units for real-time validation of rotor dynamics. Internal filter networks execute cross-talk suppression between channels, and gap voltage validation modules accurately monitor structural shaft alignment tolerances to log critical thermal or mechanical displacement anomalies.\u003c\/p\u003e\n\u003ch3\u003eLogistics Dispatch Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 1701\/15 Proximitor Input Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Assembly and Field Wiring Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Seating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSlide the card directly into its assigned slot on the 1701 FieldMonitor base unit framework. Verify internal backplane connectors align perfectly before finalizing structural retention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect field proximity sensor lines to the dedicated terminal blocks. Ensure input voltages are supplied matching the specified internal system operating ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Restrictions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTerminate individual sensor cable shield lines at the designated single reference ground bar point. Route low-voltage measurement lines through channels distinct from proximity power cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Infrastructure Verification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this monitoring card hot-swappable?\u003c\/p\u003e\n\u003cp\u003eYes, the module can be removed or inserted into an active 1701 terminal base unit without isolating power to adjacent parallel hardware loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the recommended target value for gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eStandard loops trace -10 VDC targets to ensure proximity tracking remains balanced inside the linear measurement range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the extension cable capacitance exceeds specifications?\u003c\/p\u003e\n\u003cp\u003eExceeding the 60 pF\/ft limit over long runs alters the high-frequency response loop, introducing attenuation on the raw buffered output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module be powered by an external standalone supply?\u003c\/p\u003e\n\u003cp\u003eNo, the module requires direct power input distribution of -24 V and +5 V internally routed from the integrated 1701 Power Supply module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit react to a sensor path short-circuit?\u003c\/p\u003e\n\u003cp\u003eThe diagnostic logic flags a fault if voltages exceed the -1 to -23 V gap range, triggering a hardware fault instead of an alert.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of machinery metrics does this specific variant trace?\u003c\/p\u003e\n\u003cp\u003eThe card structure is calibrated to process signals from non-contacting sensors tracking radial vibration and thrust displacement profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the buffered output feature electrical isolation?\u003c\/p\u003e\n\u003cp\u003eNo, the buffered signal paths are not isolated and require careful terminal routing to avoid ground loops with analyzer tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the update rate for software parameter updates?\u003c\/p\u003e\n\u003cp\u003eThe internal memory components maintain a fast execution cycle, delivering a data flex read\/write rate of 25 milliseconds or higher.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026837360813,"sku":"1701\/15","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/170115_2.jpg?v=1782724013","url":"https:\/\/www.maxwellplc.com\/products\/1701-15-bently-nevada-proximitor-input-monitor-1701-fieldmonitor","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}