{"product_id":"16710-25-bently-nevada-interconnect-cable","title":"16710-25 Bently Nevada Interconnect Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 16710-25\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable, operates as a dedicated hardware component for high-frequency RF signal propagation within Machinery Protection Systems. This specialized coaxial component provides the calibrated electrical connection matching the specific impedance criteria required between an eddy-current proximity probe head and a remote Proximitor processing unit.\u003c\/p\u003e\n\u003ch3\u003eLoop Interface Performance Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16710-25\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7200 \/ 3300 Transducer Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComponent Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial Interconnect Extension Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 m (approximately 82.0 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharacteristic Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 \\Omega nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (0 mA continuous loop draw)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35.0 x 35.0 x 8.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% condensing when combined with sealed connector boots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Interface Boundary Control\u003c\/h3\u003e\n\u003cp\u003eThe 25.0-meter physical configuration of this coaxial link is engineered to maintain constant capacitive and inductive parameters per unit length. Adherence to these geometric tolerances ensures that the factory eddy-current probe scaling remains precise during continuous operation. This stable electrical profile allows field technicians to execute accurate gap voltage validation targeting standard -10 VDC operational centers, while the dense inner braided shield ensures maximum cross-talk suppression between close-proximity radial vibration channels tracking rotor dynamics.\u003c\/p\u003e\n\u003ch3\u003eLoop Interface Technical Diagnostics\u003c\/h3\u003e\n\u003cp\u003eQ: What specific electrical data modifications result if the 16710-25 cable is shortened during installation?\u003c\/p\u003e\n\u003cp\u003eA: Cutting the cable alters the total loop capacitance and circuit resistance. This shift modifies the operational tuning frequency of the primary driver oscillator, invalidating the factory-calibrated eddy-current probe scaling and rendering the displacement measurements uncalibrated.\u003c\/p\u003e\n\u003cp\u003eQ: How does a leakage path to the machine frame affect the raw vibration channel?\u003c\/p\u003e\n\u003cp\u003eA: If the outer shield compromises its insulation layer and contacts the metallic machine housing, it forms a parasitic ground loop. This electrical path introduces stray industrial noise, corrupting the static gap voltage validation and inserting false spikes into the dynamic signal output.\u003c\/p\u003e\n\u003cp\u003eQ: Can this interconnect line be uncoupled while the monitor rack channel is fully energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Uncoupling the physical coaxial connection causes no electrical hardware damage. However, breaking the transmission loop forces the Proximitor voltage output to instantly saturate to its maximum negative limit, which trips active machine trip interlocks unless the channel bypass state is active.\u003c\/p\u003e\n\u003ch3\u003eMechanical Routing and Installation Layout\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Bend Constraints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum physical bend radius of 25.4 mm along the entire installation path. Kinking or pulling the cable past this limit compresses the internal dielectric core, permanently distorting the 95-\\Omega characteristic impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Environmental Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTorque the miniature coaxial connections to factory specifications using a connector wrench. Slide a dedicated connector protector sleeve over the mated joint or wrap the terminal link in clear self-fusing insulation tape to isolate it from the junction box frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Segregation Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the extension cable inside dedicated rigid or flexible liquid-tight steel conduits. Do not pull this high-frequency signal line through wireways or trays that contain high-voltage AC motor lines or variable frequency drive switching circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKit Components Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 16710-25 Coaxial Interconnect Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Engineering Terminal Schematic Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Proximity sensor tips, active Proximitor drivers, and flexible bulkhead seals must be specified and purchased as separate items.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Dispatch Logistics\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish verification is logged in the processing database. Dispatches route directly from the Xiamen, China transit node via express international transport handlers including DHL, FEDEX, or UPS. The hardware items travel protected inside heavy-duty anti-static industrial packaging enclosures layered inside rigid shock-insulated cartons with moisture desiccant packets to prevent physical deformation or electrostatic degradation during transit.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518830928045,"sku":"16710-25","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-16710-25-interconnect-cable-3wls4fl5gqf.jpg?v=1766979829","url":"https:\/\/www.maxwellplc.com\/products\/16710-25-bently-nevada-interconnect-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}