{"product_id":"16710-12-bently-nevada-interconnect-cable-transducer","title":"16710-12 Bently Nevada Interconnect Cable Transducer","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 16710-12\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable, operates as a dedicated hardware component for high-frequency RF signal propagation within Machinery Protection Systems. This specialized coaxial component provides the calibrated electrical connection matching the specific impedance criteria required between an eddy-current proximity probe head and a remote Proximitor processing unit.\u003c\/p\u003e\n\u003ch3\u003eComponent Parameter Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16710-12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7200 \/ 3300 Transducer Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Component Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial Interconnect Extension Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.0 m (approximately 39.4 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharacteristic Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 \\Omega nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (0 mA continuous loop draw)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.68 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26.5 x 26.5 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% condensing when combined with sealed connector boots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage Validation and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 12.0-meter physical configuration of this coaxial link is engineered to maintain constant capacitive and inductive parameters per unit length. Adherence to these geometric tolerances ensures that the factory eddy-current probe scaling remains precise during continuous machine cycles. This stable electrical profile allows field technicians to execute accurate gap voltage validation targeting standard -10 VDC operational centers, while the dense inner braided shield ensures maximum cross-talk suppression between close-proximity radial vibration channels to preserve raw data during rotor dynamics assessment.\u003c\/p\u003e\n\u003ch3\u003eTransducer Interface Diagnostics\u003c\/h3\u003e\n\u003cp\u003eQ: What specific data modifications occur if the 16710-12 cable length is mechanically shortened in the field?\u003c\/p\u003e\n\u003cp\u003eA: Altering the physical length changes the overall circuit capacitance and line impedance. This modification shifts the tuned frequency of the oscillator loop, invalidating the calibrated eddy-current probe scaling and causing linear voltage tracking errors at the monitor module.\u003c\/p\u003e\n\u003cp\u003eQ: How does moisture entering the coaxial connector junction alter the sensor output?\u003c\/p\u003e\n\u003cp\u003eA: Moisture ingress lowers the insulation resistance between the center conductor and the outer shield. This drop in resistance dampens the RF signal amplitude, resulting in false shifts during gap voltage validation and introducing noise into the dynamic tracking loop.\u003c\/p\u003e\n\u003cp\u003eQ: Can this interconnect line be disconnected while the active monitor channel is live?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Disconnecting the coaxial joint is safe for the hardware components. However, interrupting the loop causes the Proximitor output to instantly saturate to its maximum negative voltage limit, which will trip active safety interlocks unless the channel bypass mode is engaged.\u003c\/p\u003e\n\u003ch3\u003eMechanical Routing and Installation Layout\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a strict physical bend radius limit of 25.4 mm throughout the cable routing path. Sharp kinks compress the internal dielectric spacing layer, permanently changing the 95-\\Omega characteristic impedance profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Insulation Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTorque the miniature coaxial connections to factory specifications using a connector wrench. Enclose the finished metal joint inside a dedicated connector protector sleeve or apply thick layers of self-fusing silicone tape to prevent mechanical grounding against terminal box frames.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparation from Power Circuits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the transducer cable inside dedicated rigid or flexible liquid-tight steel conduits. Do not pull this high-frequency signal line through the same trays or wireways housing heavy AC motor leads or variable frequency drive switching lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProcurement Package Content\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 16710-12 Coaxial Interconnect Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Engineering Terminal Schematic Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Proximity sensor tips, active Proximitor drivers, and flexible bulkhead seals must be specified and purchased as separate items.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Dispatch Framework\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish verification is logged in the processing database. Dispatches route directly from the Xiamen, China transit node via express international transport handlers including DHL, FEDEX, or UPS. The hardware items travel protected inside heavy-duty anti-static industrial packaging enclosures layered inside rigid shock-insulated cartons with moisture desiccant packets to prevent physical deformation or electrostatic degradation during transit.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518826176685,"sku":"16710-12","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-16710-12-interconnect-cable-4xvrpxopuey.jpg?v=1766979693","url":"https:\/\/www.maxwellplc.com\/products\/16710-12-bently-nevada-interconnect-cable-transducer","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}