{"product_id":"16710-09-bently-nevada-interconnect-cable-proximity","title":"16710-09 Bently Nevada Interconnect Cable Proximity","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 16710-09\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16710-09\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable, operates as a dedicated hardware component for high-frequency RF signal propagation within Machinery Protection Systems. This specialized coaxial component provides the calibrated electrical connection matching the specific impedance criteria required between an eddy-current proximity probe head and a remote Proximitor processing unit.\u003c\/p\u003e\n\u003ch3\u003eElectrical and Mechanical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16710-09\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCore Application\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTurbine Supervisory Instrumentation (TSI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComponent Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial Extension Interconnect Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 m (approximately 29.5 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharacteristic Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 \\Omega nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (0 mA internal consumption)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.5 x 24.5 x 4.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% condensing when combined with sealed connector boots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Interface Boundary Control\u003c\/h3\u003e\n\u003cp\u003eThe 9.0-meter physical configuration of this coaxial link is engineered to maintain constant capacitive and inductive parameters per unit length. Adherence to these geometric tolerances ensures that the factory eddy-current probe scaling remain precise during continuous operation. This stable electrical profile allows field technicians to execute accurate gap voltage validation targeting standard -10 VDC operational centers, while the dense inner braided shield ensures maximum cross-talk suppression between close-proximity radial vibration channels.\u003c\/p\u003e\n\u003ch3\u003eTransducer Interface Troubleshooting\u003c\/h3\u003e\n\u003cp\u003eQ: What specific data modifications occur if the 16710-09 cable length is mechanically shortened in the field?\u003c\/p\u003e\n\u003cp\u003eA: Altering the physical length changes the overall circuit capacitance and line impedance. This modification shifts the tuned frequency of the oscillator loop, invalidating the calibrated eddy-current probe scaling and causing linear voltage tracking errors at the monitor module.\u003c\/p\u003e\n\u003cp\u003eQ: How does moisture entering the coaxial connector junction alter the sensor output?\u003c\/p\u003e\n\u003cp\u003eA: Moisture ingress lowers the insulation resistance between the center conductor and the outer shield. This drop in resistance dampens the RF signal amplitude, resulting in false shifts during gap voltage validation and introducing noise into the dynamic tracking loop.\u003c\/p\u003e\n\u003cp\u003eQ: Can this interconnect line be disconnected while the active monitor channel is live?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Disconnecting the coaxial joint is safe for the hardware components. However, interrupting the loop causes the Proximitor output to instantly saturate to its maximum negative voltage limit, which will trip active safety interlocks unless the channel bypass mode is engaged.\u003c\/p\u003e\n\u003ch3\u003eField Component Layout Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a strict physical bend radius limit of 25.4 mm throughout the cable routing path. Sharp kinks compress the internal dielectric spacing layer, permanently changing the 95-\\Omega characteristic impedance profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Insulation Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTorque the miniature coaxial connections to factory specifications using a connector wrench. Enclose the finished metal joint inside a dedicated connector protector sleeve or apply thick layers of self-fusing silicone tape to prevent mechanical grounding against terminal box frames.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparation from Power Circuits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the transducer cable inside dedicated rigid or flexible liquid-tight steel conduits. Do not pull this high-frequency signal line through the same trays or wireways housing heavy AC motor leads or variable frequency drive switching lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProcurement Package Content\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 16710-09 Coaxial Interconnect Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Engineering Terminal Schematic Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Proximity sensor tips, active Proximitor drivers, and flexible bulkhead seals must be specified and purchased as separate items.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Dispatch Framework\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish verification is cleared by the inventory system. Dispatches route directly from the Xiamen, China facility via prioritized international express paths handled by DHL, FEDEX, or UPS. The components travel enclosed within heat-sealed anti-static industrial packaging sleeves with moisture-absorbent packets to ensure physical shielding and prevent electrostatic degradation during transit.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518865072301,"sku":"16710-09","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-16710-09-interconnect-cable-ch0arff5h5x.jpg?v=1766980486","url":"https:\/\/www.maxwellplc.com\/products\/16710-09-bently-nevada-interconnect-cable-proximity","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}