{"product_id":"164466-01-bently-nevada-3500-22m-transient-data-interface-rack-module","title":"164466-01 Bently Nevada 3500\/22M Transient Data Interface Rack Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Bently Nevada 164466-01 is the primary processing component of the 3500\/22M Transient Data Interface (TDI),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eserving as the essential communication link for the 3500 Series machinery protection system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is engineered to bridge the gap between internal monitoring hardware and external diagnostic software platforms,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as System 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard rack interfaces,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 164466-01 possesses the advanced computational power required to capture high-resolution transient waveforms and steady-state data simultaneously.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt acts as the \"brain\" of the rack's communication bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emanaging data traffic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esystem configurations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand security protocols to ensure that critical machine health information is delivered accurately and without interruption to plant operators and engineers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eCore Hardware Parameters and Functional Specs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eComponent Identification\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3500\/22M Transient Data Interface (TDI)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrdering Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e164466-01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnergy Consumption\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e10.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Watts (Typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Connectivity\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFront-facing 10Base-T\/100Base-TX Ethernet port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnhanced I\/O Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with 100Base-FX Fiber-Optic secondary interfaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic Indicators\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LEDs for OK status,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTX\/RX traffic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTrip Multiply (TM),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Configuration validity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSecurity Controls\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePhysical keylock switch for toggling between RUN and PROGRAM modes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Addressing\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated switches supporting up to 127 unique rack addresses\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Proportions\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24.\u003c\/span\u003e\u003cspan class=\"\"\u003e1 cm x 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 cm x 24.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUnit Mass\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e85 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin of Manufacture\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Operational Scope\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 164466-01 is a critical asset for power plants,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erefineries,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand large-scale manufacturing sites that utilize \"M\" series monitors like the 3500\/42M or 3500\/40M.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts primary industrial value lies in its ability to stream complex vibration data during turbine startups,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecoast-downs,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand unexpected process excursions.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy providing a dedicated Ethernet gateway,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 164466-01 allows for seamless integration into modern plant networks,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling remote diagnostics and centralized asset condition monitoring.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module's built-in relay functionality provides a hardware-level signal for \"NOT OK\" conditions,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that any internal rack fault is immediately communicated to the central control system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhether used for new system deployments or as a critical spare for existing machinery protection loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis TDI module ensures high-bandwidth data transparency for mission-critical rotating equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: What is the purpose of the TM LED on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe TM (Trip Multiply) LED illuminates when the system is in Trip Multiply mode,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich temporarily increases alarm setpoints to allow a machine to pass through high-vibration resonance zones during startup without triggering a trip.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: Can I configure the rack settings via the front Ethernet port?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe front-panel 10\/100 Ethernet port is designed for high-speed connection to the 3500 System Configuration software,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for local or networked setup of all monitoring parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: Why does the 164466-01 include a physical keylock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe keylock provides a hardware layer of security.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn \"RUN\" mode,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe rack configuration is locked to prevent unauthorized or accidental changes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhile \"PROGRAM\" mode allows for legitimate engineering adjustments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: How does the 164466-01 handle transient waveform data differently than older modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 3500\/22M series is specifically designed with an internal communication processor that can buffer and transmit the high-density data required for waveform analysis in System 1 software,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich standard RIM modules cannot support.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: Is the 0.85 kg weight inclusive of the rear I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e85 kg weight refers to the 164466-01 main processor module.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe total weight of a complete TDI assembly will vary slightly depending on which rear I\/O module (Copper or Fiber Optic) is paired with it.\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45832621654189,"sku":"164466-01","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/140734-01-33.jpg?v=1774493363","url":"https:\/\/www.maxwellplc.com\/products\/164466-01-bently-nevada-3500-22m-transient-data-interface-rack-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}