{"product_id":"150-f85nbd-allen-bradley-smc-flex-series-smart-motor-controller","title":"150-F85NBD Allen-Bradley SMC Flex Series Smart Motor Controller","description":"\u003cp\u003eThe \u003cb\u003eAllen-Bradley 150-F85NBD\u003c\/b\u003e, also cataloged as the \u003cb\u003e150-F85NBD\u003c\/b\u003e Smart Motor Controller, operates as a dedicated hardware component for solid-state reduced voltage starting, controlled ramp acceleration, and current limiting within 3-phase AC motor circuits.\u003c\/p\u003e\n\u003ch3\u003ePart Number Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e150-F\u003c\/b\u003e: Bulletin 150 SMC Flex solid-state soft starter platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e85\u003c\/b\u003e: 85 A continuous current rating supporting 15 to 60 hp motors at 460 VAC line input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eN\u003c\/b\u003e: Open enclosure construction intended for direct mounting inside an electrical control panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eB\u003c\/b\u003e: 200...480 VAC 3-phase main input operating voltage threshold at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eD\u003c\/b\u003e: 100...240 VAC control circuit input rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Physical \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150-F85NBD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.06 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.8 x 24.0 x 21.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Internal Logic Dissipation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200...480 VAC (3-Phase, 50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 hp (15 to 60 hp @ 460 VAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100...240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrame Construction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Capabilities\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Soft Start, Current Limit Acceleration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFieldbus Integration \u0026amp; Controller Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe solid-state motor controller transmits internal operating status, motor load metrics, and trip diagnostics over EtherNet\/IP deterministic networks through optional communication module adapters. Internal controller logic preserves strict firmware flash compatibility across network nodes, preventing data handshake delays and timing jitter during continuous programmable logic processor sweeps.\u003c\/p\u003e\n\u003ch3\u003eStandard Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Allen-Bradley 150-F85NBD Smart Motor Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Field Wiring and Technical Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Assembly \u0026amp; Electrical Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePanel Mounting Orientation\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFasten the open unit vertically on a clean, unpainted metal mounting plate inside a protective enclosure to allow unobstructed convective heat sink cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Terminal Wiring\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSecure 3-phase incoming power lines to L1, L2, L3 and motor leads to T1, T2, T3 according to marked terminal torque values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl Circuit Isolation\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate 100...240 VAC control supply conductors from high-voltage main power cables to prevent inductive noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarth Grounding Protocol\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRun a heavy-gauge copper bonding conductor directly from the main cabinet ground bar to the controller protective earth terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Engineering Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the max continuous output current rating of the 150-F85NBD?\u003c\/p\u003e\n\u003cp\u003eThe controller supports a continuous operational output current rating of 85 A for 3-phase induction motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control voltage must be connected to the control terminals?\u003c\/p\u003e\n\u003cp\u003eThe internal control circuit requires a single-phase AC control voltage input source ranging from 100 VAC to 240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan power lines be connected or serviced while control power is active?\u003c\/p\u003e\n\u003cp\u003eNo, both the 3-phase AC main line power and AC control supply inputs must be de-energized prior to terminal servicing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat motor power capacity can this unit handle at 460 VAC input?\u003c\/p\u003e\n\u003cp\u003eThe module manages 3-phase induction motor applications rated from 15 hp up to 60 hp at 460 VAC operating line voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external protective cabinet required for this controller model?\u003c\/p\u003e\n\u003cp\u003eYes, because this starter features an open enclosure design, it must be installed inside a suitable industrial enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit maintain data consistency across communication buses?\u003c\/p\u003e\n\u003cp\u003eOptional communication interface cards connect to control registers while maintaining firmware flash compatibility across nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat main line input voltage parameters apply to the power terminals?\u003c\/p\u003e\n\u003cp\u003eThe main power circuit accepts 3-phase AC operating line voltages ranging from 200 VAC to 480 VAC at 50\/60 Hz frequency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal considerations are required during panel installation?\u003c\/p\u003e\n\u003cp\u003eThe starter must be mounted strictly in a vertical orientation to facilitate proper convective heat dissipation through its heat sinks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066396954797,"sku":"150-F85NBD","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_1-4_3f07f579-e9ed-4de5-b59f-4ff8d5d68757.jpg?v=1786074238","url":"https:\/\/www.maxwellplc.com\/products\/150-f85nbd-allen-bradley-smc-flex-series-smart-motor-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}