{"product_id":"150-f25nbd-allen-bradley-smc-flex-series-smart-motor-controller","title":"150-F25NBD Allen-Bradley SMC Flex Series Smart Motor Controller","description":"\u003cp\u003eThe \u003cb\u003eAllen-Bradley 150-F25NBD\u003c\/b\u003e, also cataloged as the \u003cb\u003e150-F25NBD\u003c\/b\u003e Smart Motor Controller, operates as a dedicated hardware component for solid-state soft starting, acceleration ramp profiling, and current limit execution within 3-phase AC motor control systems.\u003c\/p\u003e\n\u003ch3\u003eCatalog Designation Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e150-F\u003c\/b\u003e: Bulletin 150 SMC Flex solid-state motor controller base unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e25\u003c\/b\u003e: 25 A continuous current output capacity supporting up to 15 hp motors at 460 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eN\u003c\/b\u003e: Open enclosure design intended for protective industrial control panel mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eB\u003c\/b\u003e: 200...480 VAC 3-phase power line input range at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eD\u003c\/b\u003e: 100...240 VAC control circuit operational threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Operating Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150-F25NBD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.06 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.8 x 24.0 x 21.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Internal Logic Dissipation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e460 VAC (Input Line: 200...480 VAC, 3-Phase, 50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 hp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100...240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Capabilities\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSoft Start, Current Limit Acceleration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Routing \u0026amp; Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe smart motor controller routes diagnostic feedback and current metrics across EtherNet\/IP deterministic networks via optional communication adapters. Embedded control microcode retains firmware flash compatibility, preventing checksum errors and transmission delays during remote parameter synchronization or real-time PLC automation sweeps.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivery Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Allen-Bradley 150-F25NBD Smart Motor Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation Instruction Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Field Wiring Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Enclosure Mounting\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFasten the open-style unit vertically onto an unpainted metal backpanel inside a NEMA or IP rated enclosure to permit unimpeded air convection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Terminal Connections\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate 3-phase AC power lines to terminals L1, L2, L3 and motor leads to T1, T2, T3 according to marked terminal screw torque limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl Line Isolation\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate 100...240 VAC control supply wiring from high-power load conductors to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarth Grounding Integrity\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBond a low-impedance copper ground wire directly from the industrial panel ground bar to the chassis protective earth ground terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical System FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the continuous current rating of the 150-F25NBD controller?\u003c\/p\u003e\n\u003cp\u003eThe controller provides a continuous maximum output current rating of 25 A for 3-phase induction motor loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control voltage input is required for logic operations?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a single-phase AC control voltage input source ranging from 100 VAC to 240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan main line power be connected while control circuit wiring is modified?\u003c\/p\u003e\n\u003cp\u003eNo, both 3-phase line power and AC control supply inputs must be completely isolated before servicing terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat motor power capacity does this unit control at 460 VAC line input?\u003c\/p\u003e\n\u003cp\u003eThe module manages 3-phase induction motor applications rated up to 15 hp at 460 VAC nominal system voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external panel required to house the 150-F25NBD assembly?\u003c\/p\u003e\n\u003cp\u003eYes, because this model uses an open enclosure design, it must be installed within a protective industrial cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit maintain network parameter consistency?\u003c\/p\u003e\n\u003cp\u003eCommunication option cards interface with internal registers while preserving firmware flash compatibility across nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat main line voltage limits apply to the power terminals?\u003c\/p\u003e\n\u003cp\u003eThe power circuit accommodates 3-phase AC operating input line voltages from 200 VAC to 480 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cooling precautions must be taken during cabinet setup?\u003c\/p\u003e\n\u003cp\u003eMount the module strictly in a vertical orientation to enable heat sink thermal dissipation during continuous duty cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066384240813,"sku":"150-F25NBD","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_6-5_79053d14-6cf4-473a-be8f-7ec959918fbd.jpg?v=1786074785","url":"https:\/\/www.maxwellplc.com\/products\/150-f25nbd-allen-bradley-smc-flex-series-smart-motor-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}