{"product_id":"140cpu67160s-schneider-electric-modicon-quantum-unity-safety-processor","title":"140CPU67160S Schneider Electric Modicon Quantum Unity Safety Processor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Schneider Electric 140CPU67160S is a premium-grade safety CPU engineered for the Modicon Quantum automation platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis \"S\" variant is specifically developed for Unity Safety systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the high-integrity processing required for failsafe industrial operations.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOperating on the Unity Pro XL Safety software environment,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis processor executes rigorous safety logic to protect personnel,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emachinery,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand the environment.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt acts as the central intelligence in a Safety Instrumented System (SIS),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that critical processes are brought to a predefined safe state whenever a fault or dangerous condition is detected.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts architecture is optimized for high-speed computation and redundant communication,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it a cornerstone for high-availability safety architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eFunctional Specifications and Hardware Profile\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis processor module is designed to occupy a standard Quantum backplane,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eutilizing high-performance internal circuitry and reliable battery backup to maintain safety parameters during power cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMain Processor Frequency:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e266 MHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSoftware Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUnity Pro XL Safety\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRemote I\/O Support:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 31 stations (maximum 1 rack per station)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBus Current Requirement:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2500 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eData Integrity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3V DC Lithium Battery (Model 990XCP98000)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommunication Interfaces:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in ports for network integration and Hot Standby synchronization\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChassis Width:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOccupies 2 slots in a Quantum rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e250 mm (Height) x 130 mm (Depth) x 80 mm (Width)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNet Weight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e18 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFrance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStatus:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eActive \/ Available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eCritical Safety Applications and Industrial Use\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEmergency Shutdown Systems (ESD)\u003c\/strong\u003e\u003cspan class=\"\"\u003eIn the petrochemical and oil \u0026amp; gas sectors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 140CPU67160S is utilized as the primary controller for Emergency Shutdown Systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt monitors pressure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etemperature,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand leak detection sensors across the facility,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the deterministic response times required to close isolation valves and vent hazardous gases during an incident.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBurner Management Systems (BMS)\u003c\/strong\u003e\u003cspan class=\"\"\u003eFor large-scale power generation and industrial boilers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis safety processor manages the complex ignition and fuel-shutoff sequences.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy implementing failsafe logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit prevents the accumulation of unburned fuel,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethereby mitigating the risk of boiler explosions and ensuring compliance with international safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNuclear and Hazardous Waste Processing\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe high reliability and extensive diagnostic capabilities of the Modicon Quantum Safety series make this CPU ideal for nuclear facility control and hazardous material handling.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts ability to manage up to 31 remote I\/O stations allows for distributed safety monitoring across large-scale,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ehigh-risk containment areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFire and Gas Detection Networks\u003c\/strong\u003e\u003cspan class=\"\"\u003eIn offshore platforms and chemical plants,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 140CPU67160S processes inputs from flame,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esmoke,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand toxic gas detectors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts robust processing power ensures that even in complex networks with high I\/O counts,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esafety actions such as activating fire suppression or initiating site-wide alarms are executed without delay.\u003c\/span\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45519024357549,"sku":"140CPU67160S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/schneider-electric-140cpu67160s-unity-security-processor-yrinxnbdogc.jpg?v=1766984988","url":"https:\/\/www.maxwellplc.com\/products\/140cpu67160s-schneider-electric-modicon-quantum-unity-safety-processor","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}