{"product_id":"140aci03000-schneider-electric-analogue-input-module-modicon-quantum","title":"140ACI03000 Schneider Electric Analogue Input Module Modicon Quantum","description":"\u003cp\u003eConfigured for high-precision signal acquisition in Modicon Quantum automation platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric 140ACI03000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e140ACI03000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalogue Input Module) provides direct physical electrical execution for 8 differential analogue input channels across industrial control architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 140ACI03000 identifies a standard-format analogue input module supporting 12-bit resolution. The model signifies a multi-range configuration capable of processing both 1 V to 5 V voltage signals and 4 mA to 20 mA current loops, utilizing a single-pole low-pass filter with a -3 dB cutoff at 15 Hz to mitigate high-frequency noise.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140ACI03000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to product labeling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.8 cm x 16.5 cm x 31.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 W (240 mA at backplane bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalogue Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Differential\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 bits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModicon Quantum Backplane Bus Communication Velocity\u003c\/h3\u003e\n\u003cp\u003eThe Modicon Quantum architecture requires precise backplane bus communication velocity to maintain real-time data integrity. The 140ACI03000 requires 9 input words for data mapping. System performance is contingent upon ensuring that I\/O density scaling does not exceed the module's 5 ms update time. Engineers must account for the deterministic nature of the Quantum rack bus to ensure firmware flash compatibility and synchronous data exchange during high-speed process monitoring.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 140ACI03000 Analogue input module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Field wiring should be verified for loop impedance requirements; 250 Ohm resistors are integrated for current mode operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Seat the module into the designated Modicon Quantum rack slot. Ensure the backplane connector is fully engaged and the module is secured by the mechanical latch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Utilize shielded twisted pair cabling for all differential inputs. Ground the shield at the cabinet entry point to minimize electromagnetic field interference (10 V\/m rating).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection: Ensure field signal levels do not exceed the 50 VDC \/ 25 mA absolute maximum input thresholds to prevent permanent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironment: Install within an IP20 environment. Ensure the rack chassis is bonded to a low-impedance earth ground to satisfy electrostatic discharge (4 kV contact \/ 8 kV air) requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 140ACI03000 hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: Yes, this module supports hot-swapping within a powered Modicon Quantum rack, allowing for maintenance without interrupting the backplane communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the isolation level between channels and the bus?\u003c\/p\u003e\n\u003cp\u003eA: The module provides 1000 VDC continuous isolation and is hi-pot tested to 3000 VDC for 60 seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the module detect fault conditions?\u003c\/p\u003e\n\u003cp\u003eA: The module performs automatic diagnostics, detecting broken wires for 4-20 mA loops and undervoltage conditions for 1-5 V inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the input impedance for voltage signals?\u003c\/p\u003e\n\u003cp\u003eA: In voltage mode, the input impedance is greater than 20 MOhm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the filtering adjustable?\u003c\/p\u003e\n\u003cp\u003eA: The module includes a fixed single-pole low-pass filter with a cutoff at 15 Hz +\/- 20 %.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the module status communicated?\u003c\/p\u003e\n\u003cp\u003eA: The module features front-panel LEDs for bus communication (Active), channel activation (8), and fault diagnostics (8 per channel + 1 module fault).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum operating altitude?\u003c\/p\u003e\n\u003cp\u003eA: The module is rated for reliable operation up to an altitude of 5000 m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the module compatible with older Quantum CPUs?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility is generally maintained; however, ensure the CPU firmware version supports the 9-word input addressing requirement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46474004889773,"sku":"140ACI03000","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/140ACI03000-13.jpg?v=1782808026","url":"https:\/\/www.maxwellplc.com\/products\/140aci03000-schneider-electric-analogue-input-module-modicon-quantum","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}