{"product_id":"136711-02-bently-nevada-temperature-monitoring-module-3500-series","title":"136711-02 Bently Nevada Temperature Monitoring Module 3500 Series","description":"\u003cp\u003eConfigured for multi-channel thermal data acquisition in 3500 machinery protection system platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 136711-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3500\/61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTemperature Monitor) provides direct physical and electrical processing of RTD and thermocouple inputs for rotational asset monitoring.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration and Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 136711-02 denotes a specific hardware revision of the 3500\/61 monitor, featuring a 6-channel input architecture. The module design incorporates internal signal termination and isolation circuitry to interface with field-mounted temperature sensors. It processes raw transducer signals into digital values for alarm logic execution and rack-based data communication via the 3500 series backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e136711-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.94 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.3 cm x 18.5 cm x 24.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 deg C to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/61 module maintains strict signal integrity by employing cross-talk suppression techniques across its six input channels. When paired with machine-side sensors, the monitor performs gap voltage validation and signal scaling consistent with Bently Nevada transducer standards. The hardware manages internal state machine transitions to monitor for signal saturation, ensuring that erroneous readings do not trigger unintended alarm relays. This includes continuous monitoring of lead-wire resistance in RTD configurations to compensate for measurement drift.\u003c\/p\u003e\n\u003ch3\u003eOrdering and Packaging\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e136711-02 Temperature Monitor module (Main board assembly)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard I\/O module (Terminal block type specific to sensor input)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser documentation and configuration guidelines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEMI\/RFI shielding components for terminal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Field Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the module is inserted into a dedicated slot within the 3500 rack backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtilize shielded twisted-pair cables for all sensor signal runs to prevent ground-loop induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that terminal block wiring is secured to meet the required torque specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm that the module software configuration matches the specific physical sensor type (RTD or Thermocouple) to prevent scaling errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain clear airflow paths around the 3500 rack to ensure internal module dissipation remains within operational limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the 3500\/61 support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is designed to be removed or inserted into the 3500 rack backplane while the system is powered without causing rack-wide communication disruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this module detect sensor cable breaks?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the internal diagnostic logic monitors for open-circuit and short-circuit conditions, flagging a \"Not OK\" status when input resistance exceeds defined thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the module handle signal isolation?\u003c\/p\u003e\n\u003cp\u003eA: The module employs galvanic isolation between the sensor input channels and the backplane circuitry to prevent interference from ground potential differences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the impact of the 50 kHz output frequency?\u003c\/p\u003e\n\u003cp\u003eA: This frequency relates to the sampling and signal conditioning internal processing speed required to maintain real-time monitoring and timely alarm relay activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this module compatible with existing 3500 RIM modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is fully compatible with the 3500 Rack Interface Module (RIM) for status reporting and configuration data transfer via Ethernet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How are alarms configured on this module?\u003c\/p\u003e\n\u003cp\u003eA: Alarms are configured via the 3500 Rack Configuration software, which sets alert\/danger setpoints for each of the six input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does it require external signal conditioning?\u003c\/p\u003e\n\u003cp\u003eA: No, the 3500\/61 provides all necessary excitation and amplification for standard RTDs and thermocouples internally.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a module failure?\u003c\/p\u003e\n\u003cp\u003eA: The \"OK\" LED on the front faceplate will turn off, and a system-level fault will be reported to the RIM and displayed in the configuration software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378091679917,"sku":"136711-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-3500-61-136711-02-temperature-module-cnm5uk4ps0a.jpg?v=1764225521","url":"https:\/\/www.maxwellplc.com\/products\/136711-02-bently-nevada-temperature-monitoring-module-3500-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}