{"product_id":"133292-01-bently-nevada-3500-15-power-supply-module-low-voltage-dc","title":"133292-01 Bently Nevada 3500\/15 Power Supply Module Low-Voltage DC","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15 133292-01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Module, operates as a dedicated hardware component for converting line power to rack-level DC voltages within 3500 monitoring system platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/15\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e133292-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Family:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500 System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/15 (133292-01)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.0 x 9.5 x 21.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +90 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/15 power supply module serves as the primary source for backplane bus distribution, ensuring stable voltage levels for all modules within the 3500 rack. During the calibration of rotor dynamics monitoring loops, this module maintains the electrical stability necessary for precise eddy-current probe scaling. To ensure measurement integrity across the TSI platform, the power supply is designed for cross-talk suppression, preventing ripple noise from interfering with sensitive vibration signals. Proper installation requires validation of the output bus voltage to ensure targets like -10 VDC at the probe driver interface remain within nominal limits.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 3500\/15 Power Supply Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation and safety manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard rack mounting accessories.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInsert the module into the designated power supply slot in the 3500 rack; ensure the backplane connection is secure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect primary AC\/DC input power to the module input terminals; verify input voltage ranges match module specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the chassis ground terminal to a low-impedance facility earth to provide surge protection and electromagnetic compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf dual power supplies are utilized, confirm proper load sharing between modules to ensure continuous operation during a single module failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the 3500\/15 can be removed and inserted into a powered rack, provided the system configuration allows for redundant power supply operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are faults communicated?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features front-panel LEDs to indicate power status; fault states are communicated to the system via the Rack Interface Module (RIM).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require external cooling?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module relies on passive heat dissipation; ensure the rack has adequate airflow according to the 3500 installation manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in redundant configurations?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the 3500 system supports dual power supplies for load sharing and high availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the effect of input voltage fluctuation?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal regulator circuitry maintains stable output voltages within defined limits; ensure the source remains within nominal operating specs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the output voltage configurable?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the module provides fixed output voltages compatible with 3500 system module requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance is required?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoutine inspection of terminal connections and ensuring the module remains free of accumulated dust is recommended.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the IP rating defined?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IP67 rating applies to the module's enclosure design; ensure the rack mounting environment meets these standards if required by the site application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378089091245,"sku":"133292-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-3500-15-133292-01-low-voltage-dc-power-supply-module-cxxxu02b1cn.jpg?v=1764225483","url":"https:\/\/www.maxwellplc.com\/products\/133292-01-bently-nevada-3500-15-power-supply-module-low-voltage-dc","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}