{"product_id":"12p1731x062-emerson-deltav-8-channel-analog-input-card-kj3002x1-bg2","title":"12P1731X062 Emerson DeltaV 8-Channel Analog Input Card KJ3002X1-BG2","description":"\u003ch3\u003e12P1731X062 Emerson DeltaV 8-Channel Analog Input Card KJ3002X1-BG2\u003c\/h3\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-2178 citation-end-2178\"\u003eThe Emerson KJ3002X1-BG2 (Part Number 12P1731X062) is a precision 8-channel Analog Input module engineered for the DeltaV™ M-series I\/O Subsystem.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis module is specifically designed to interface with millivolt-level signals and thermocouple temperature sensors, providing the high-resolution data acquisition required for complex thermal process control. By converting low-level analog voltages into digital values for the Distributed Control System (DCS), the KJ3002X1-BG2 ensures accurate monitoring of critical temperature variables across a wide industrial spectrum.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eOperating as a core component of the M-series hardware, this module facilitates seamless integration of temperature sensing without the need for external signal conditioners or transmitters.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-2177 citation-end-2177\"\u003eIt features advanced cold-junction compensation and signal linearization, ensuring that temperature readings remain accurate despite fluctuations in the ambient environment of the control cabinet.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Characteristics and Strategic Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe KJ3002X1-BG2 is defined by its architectural flexibility and its ability to maintain signal integrity in electrically noisy industrial settings.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e8-Channel High-Resolution Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports eight independent channels of thermocouple or millivolt (mV) inputs, optimizing rack space and reducing the cost per point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-2176\"\u003e\u003c\/span\u003e\u003cstrong\u003eIntegrated Cold-Junction Compensation:\u003c\/strong\u003e\u003cspan class=\"citation-2176 citation-end-2176\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures high-precision onboard sensors to compensate for the reference junction, maintaining measurement accuracy across the module's full operating range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with redundant I\/O carriers. When deployed in a redundant pair, the system ensures \"bumpless\" switchover if a hardware fault occurs, maintaining continuous process visibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides robust electrical isolation between the field-side sensors and the system backplane, protecting the controller from ground loops and transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for the replacement of the module under system power (RIUP), enabling maintenance activities without interrupting the communication bus or adjacent I\/O cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan class=\"citation-2175 citation-end-2175\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to meet ISA-S71.04 Class G3 standards, providing reliable operation in corrosive environments where airborne contaminants may be present.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmerson (Fisher-Rosemount)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Designation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKJ3002X1-BG2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Reference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12P1731X062\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-2174\"\u003e\u003c\/span\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan class=\"citation-2174 citation-end-2174\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Input (Thermocouple \/ mV)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Platform:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDeltaV™ M-series I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCarrier-based (Localbus interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.3 x 12.5 x 10.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eThe Emerson 12P1731X062 Analog Input card is essential for high-precision thermal management in several key sectors:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical Refining:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring reactor bed temperatures and distillation column thermal profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracking boiler tube temperatures and turbine exhaust gas profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Manufacturing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaging exothermic reaction temperatures where precise control is critical for safety and yield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMetal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupervising furnace temperatures and heat treatment cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45519096971437,"sku":"12P1731X062","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/emerson-kj3002x1-bg2-12p1731x062-analog-input-module-0xpxacr4em0.jpg?v=1766987020","url":"https:\/\/www.maxwellplc.com\/products\/12p1731x062-emerson-deltav-8-channel-analog-input-card-kj3002x1-bg2","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}