{"product_id":"12p1562x012-ve3051co-emerson-kj4001x1-ba2-deltav-fieldbus-interface-card","title":"12P1562X012 VE3051CO Emerson KJ4001X1-BA2 DeltaV Fieldbus Interface Card","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Emerson KJ4001X1-BA2,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ealso identified by assembly numbers VE3051CO and 12P1562X012,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized FOUNDATION™ Fieldbus H1 interface card designed for the DeltaV™ M-series I\/O subsystem.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module acts as the digital communication gateway between the DeltaV controller and field-based smart devices,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as transmitters and valve positioners.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting true digital bus communication,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe KJ4001X1-BA2 enables the transmission of multiple process variables and advanced diagnostic data over a single pair of wires.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis card is fundamental for modernizing industrial plants that require high-density device integration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reducing the wiring footprint while maximizing the information flow from the process floor to the control room.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Architecture and Engineering Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Identification\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eKJ4001X1-BA2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePart Numbers\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVE3051CO \/ 12P1562X012\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProtocol Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFOUNDATION™ Fieldbus H1 (31.\u003c\/span\u003e\u003cspan class=\"\"\u003e25 kbit\/s)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Family\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDeltaV™ M-series DCS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCard Density\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDual-port H1 interface supporting multiple devices per segment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Management\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized low-current consumption for high-efficiency I\/O racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Mass\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e22 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUnit Dimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e10.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 cm x 4.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 cm x 17.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostics\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eReal-time monitoring of segment voltage and device communication health\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTariff Code\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Networking Deployments\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe KJ4001X1-BA2 Fieldbus Card is a critical asset for sites leveraging high-speed digital plant architectures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSmart Instrumentation Networks\u003c\/strong\u003e\u003cspan class=\"\"\u003eManaging multi-drop digital segments in petrochemical and chemical facilities,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhere a single card can communicate with a variety of pressure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etemperature,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand level transmitters on a digital bus.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAdvanced Asset Management\u003c\/strong\u003e\u003cspan class=\"\"\u003eFacilitating the pass-through of AMS (Asset Management Solutions) data,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing engineers to perform remote calibration and valve signature analysis without field intervention.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePredictive Maintenance Frameworks\u003c\/strong\u003e\u003cspan class=\"\"\u003eUtilizing the card's ability to extract status bits from field devices,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling the control system to alert operators of impending instrument failures before they impact the process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eGreenfield and Expansion Projects\u003c\/strong\u003e\u003cspan class=\"\"\u003eReducing capital expenditure (CAPEX) by minimizing the requirement for traditional I\/O termination cabinets,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eas the Fieldbus architecture allows for significantly less field wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLegacy M-series Sustenance\u003c\/strong\u003e\u003cspan class=\"\"\u003eServing as a primary replacement for older revision Fieldbus cards in existing DeltaV installations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring continued support for H1 segments in facilities operating under original M-series specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45519085633709,"sku":"12P1562X012","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/emerson-kj4001x1-ba2-ve3051co-12p1562x012-deltav-fieldbus-card-12dwvbsnoro.jpg?v=1766986594","url":"https:\/\/www.maxwellplc.com\/products\/12p1562x012-ve3051co-emerson-kj4001x1-ba2-deltav-fieldbus-interface-card","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}