{"product_id":"125840-02-bently-nevada-3500-15-low-voltage-ac-power-input-module","title":"125840-02 Bently Nevada 3500\/15 Low Voltage AC Power Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-700 citation-end-700\"\u003eThe Bently Nevada 125840-02 is a dedicated Low Voltage AC Power Input Module (PIM) designed as the foundational power entry point for the 3500\/15 machinery protection system.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis component is situated at the rear of the monitoring rack, where it accepts single-phase utility power and filters it before distribution to the internal power supply modules.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-699 citation-end-699\"\u003eBy providing high-integrity isolation and surge protection, the 125840-02 ensures that the sensitive vibration, speed, and position monitoring electronics within the rack are shielded from line-side electrical noise and transients.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is an essential hardware element for maintaining the continuous surveillance and automated protection of critical rotating industrial assets.\u003c\/p\u003e\n\u003ch3\u003eHardware Infrastructure and Power Metrics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Designation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLow Voltage AC Power Input Module (PIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Identifier\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125840-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-698\"\u003e\u003c\/span\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003cspan class=\"citation-698 citation-end-698\"\u003e\u003cspan\u003e \u003c\/span\u003eSingle-phase 100-240VAC\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Frequency\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\/60Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500VAC @ 60Hz for 60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Performance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 70°C (Operating) \/ -40°C to 85°C (Storage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity Tolerance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated overvoltage, undervoltage, and short-circuit shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-697\"\u003e\u003c\/span\u003e\u003cstrong\u003eChassis Dimensions\u003c\/strong\u003e\u003cspan class=\"citation-697 citation-end-697\"\u003e\u003cspan\u003e \u003c\/span\u003e3cm x 13cm x 13cm\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Utility and Site Deployment\u003c\/h3\u003e\n\u003cp\u003eThis PIM is primarily utilized in global power generation, petrochemical, and manufacturing facilities where the Bently Nevada 3500 series acts as the primary safety loop for high-value turbines and compressors. Within a redundant system architecture, the 125840-02 facilitates the secure connection of low-voltage AC mains to the chassis backplane. Its 0.3 kg lightweight but ruggedized construction is designed for 24\/7 operation in harsh cabinet environments.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-696 citation-end-696\"\u003eBecause it complies with Overvoltage Category II standards, it provides a reliable buffer for the 3500 power supplies, ensuring that any fluctuations in the plant's power grid do not compromise the accuracy of the turbine supervisory instrumentation (TSI).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-695 citation-end-695\"\u003eThe module’s Modbus RTU interface via RS485 further allows for remote monitoring of the power status, supporting modern predictive maintenance and system diagnostics.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 125840-02 function as a standalone power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 125840-02 is a Power Input Module (PIM). It acts as the physical terminal and filter for incoming AC lines, which then feed the actual power supply modules located at the front of the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module handle 110V and 220V standard industrial feeds?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-694 citation-end-694\"\u003eA: Yes, the 125840-02 supports a broad input range from 100VAC to 240VAC, making it compatible with the majority of international industrial low-voltage AC power grids.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 125840-02 compatible with High Voltage DC power supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This specific PIM is designed for AC input only. To use a High Voltage DC power supply in your 3500 rack, you must install the corresponding DC Power Input Module designated for those voltage levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the isolation voltage rating benefit the system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1500VAC isolation provides a robust safety barrier between the utility power lines and the internal communication bus of the 3500 system, preventing high-voltage faults from damaging the monitoring modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the \"Overvoltage Category II\" rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This rating indicates the module's ability to withstand transient impulses typically found in energy-consuming equipment supplied from a fixed installation, such as a localized plant power circuit.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45832415117485,"sku":"125840-02","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/BentlyNevada125840-02_2.jpg?v=1773889550","url":"https:\/\/www.maxwellplc.com\/products\/125840-02-bently-nevada-3500-15-low-voltage-ac-power-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}