{"product_id":"10208-2-1-honeywell-fail-safe-control-fsc-interface-relay-output-module","title":"10208\/2\/1 Honeywell Fail Safe Control (FSC) Interface Relay Output Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell 10208\/2\/1 is a high-integrity relay output interface designed specifically for the Fail Safe Control (FSC) system architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module serves as a critical bridge between the safety logic solver and high-power field equipment,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding physical isolation and robust switching capabilities for discrete control signals.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for safety-instrumented functions (SIF),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 10208\/2\/1 ensures that emergency commands—such as opening a breaker or closing a fuel valve—are executed with deterministic reliability.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts design incorporates advanced diagnostic feedback to monitor relay health,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it a cornerstone for maintaining the Safety Integrity Level (SIL) within a Distributed Control System (DCS) environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Performance and Hardware Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Identification\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e10208\/2\/1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Type\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDiscrete Relay Output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Family\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell FSC (Fail Safe Control)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Proportions\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2 x 18.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 x 12.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUnit Mass\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e14 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSwitching Logic\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIsolated dry contacts for high-reliability interlocks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMonitoring\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated real-time contact status diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUnited States (USA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHS Classification\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLifecycle Status\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eLegacy Spare Support (Discontinued by OEM in 2018)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eStrategic Industrial Implementations\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 10208\/2\/1 is utilized in heavy industrial environments where the fail-safe operation of mechanical equipment is mandatory.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eOil and Gas Refineries\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is the preferred module for managing Emergency Shutdown (ESD) valves,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhere the relay must maintain a specific state during power fluctuations.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePower Plant Operations\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module provides the necessary isolation for motor control centers (MCC) and turbine trip solenoids.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is also extensively used in\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eChemical Processing Facilities\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efor burner management systems (BMS),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring fuel lines are securely isolated if a safety threshold is breached.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBecause of its modular FSC design,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit allows for easy retrofitting into existing racks,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a cost-effective path for extending the service life of certified safety systems while ensuring precise,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003elow-latency execution of safety logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518924742829,"sku":"10208\/2\/1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-10208-2-1-relay-output-module-phtpcnvt2nj.jpg?v=1766981890","url":"https:\/\/www.maxwellplc.com\/products\/10208-2-1-honeywell-fail-safe-control-fsc-interface-relay-output-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}