{"product_id":"10030-05-30-05-02-bently-nevada-series-10000-proximity-probe","title":"10030-05-30-05-02 Bently Nevada Series 10000 Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 10030-05-30-05-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe utilized to execute noncontacting static and dynamic displacement measurements across Series 10000 platforms.\u003c\/p\u003e\n\u003ch3\u003ePart Number Option Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe option suffix configuration codes determine the physical dimensions and cable termination parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10030\u003c\/strong\u003e: Base model series for the Series 10000 5 mm Proximity Probe (M10 x 1.0 thread metric design).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Represents an unthreaded case length of 0.5 in.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-30\u003c\/strong\u003e: Represents an overall case length of 3.0 in.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Identifies a total cable length of 0.5 m (approx. 20 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Equipped with a miniature male coaxial connector without connector protector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10030-05-30-05-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e58.5 x 1.5 x 1.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +100 deg C (Standard Range) \/ up to +150 deg C (Extended Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-50 to +120 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer; powered by remote -18 VDC to -26 VDC loop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1.0 (Metric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.08 to 0.18 inches (approx. 2.0 to 4.5 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 mV\/mil (approx. 7.87 V\/mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Hz (DC) to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithin +\/-0.15 % per deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Integration\u003c\/h3\u003e\n\u003cp\u003eThe 10030-05-30-05-02 proximity probe generates a high-frequency electromagnetic field at its tip to support eddy-current probe scaling when matched with a Series 10000 Proximitor Sensor. As the target surface moves within the probe's magnetic field, induction changes alter the transducer loop impedance. The resulting variations are output as an analog voltage directly proportional to the physical gap, serving as an input for monitoring complex rotor dynamics such as radial shaft vibration, thermal growth, and axial thrust displacement.\u003c\/p\u003e\n\u003cp\u003eTo secure accurate measurement limits, proper gap voltage validation (-10 VDC targets) must be verified during installation. With the probe positioned near the midpoint of its linear range, the DC gap voltage at the Proximitor output is set to -10 VDC. Proper calibration alignment ensures a stable scale factor of 200 mV\/mil and optimizes cross-talk suppression when multiple 5 mm probes are mounted within close axial proximity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 10030-05-30-05-02 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Metric hex locknuts (M10 x 1.0 thread)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerifying Radial Clearance and Positioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure a minimum radial clearance of 7.6 mm (0.30 in) from any adjacent metal casing to prevent shielding errors. Hand-thread the metric body carefully into the mounting tap to avoid damage to the M10 x 1.0 threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection and Ground Isolation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe miniature coaxial connector must remain completely dry and isolated from the machine housing. Protect the mated coaxial connection with an insulating sleeve to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImpedance-Safe Cable Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvoid routing the integrated 0.5-meter cable adjacent to high-current conduit. Secure the cable with a minimum bend radius of 25.4 mm (1.0 in) to preserve signal integrity and internal impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the physical target gap calibrated during field setup?\u003c\/p\u003e\n\u003cp\u003eAdjust the probe depth in the mounting tap until the DC gap voltage at the Proximitor output reads -10 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this metric probe interchangeable with standard 3\/8-24 UNF threaded systems?\u003c\/p\u003e\n\u003cp\u003eNo, the physical threads are metric M10 x 1.0. Attempting to force-fit this into a UNF tapped hole will destroy the threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the physical cable bend is tighter than 25.4 mm?\u003c\/p\u003e\n\u003cp\u003eSevere bends compress the internal dielectric, changing the coaxial impedance and generating electrical noise in the vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be connected directly to a 3300 XL Proximitor?\u003c\/p\u003e\n\u003cp\u003eNo, Series 10000 5 mm probes are designed for use with their corresponding Series 10000 Proximitors and extension cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the standard target material calibration for this probe?\u003c\/p\u003e\n\u003cp\u003eStandard calibration is matched to AISI E4140 steel targets. Using other metal alloys requires recalibration of the scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe assembly rated for continuous use above 100 deg C?\u003c\/p\u003e\n\u003cp\u003eYes, this model supports an extended operating temperature range up to +150 deg C when used within rated limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this passive sensor require independent power wiring?\u003c\/p\u003e\n\u003cp\u003eNo, the probe is passive and draws its operating loop voltage from the -18 VDC to -26 VDC supply provided by the remote Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the monitor rack channel if the coaxial connector is unplugged?\u003c\/p\u003e\n\u003cp\u003eThe monitoring system will immediately register an open-circuit loop fault, triggering a \"Not OK\" status and disabling alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026438148269,"sku":"10030-05-30-05-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--3_68015543-ef5d-4709-a859-ef85e00baa79.jpg?v=1784282485","url":"https:\/\/www.maxwellplc.com\/products\/10030-05-30-05-02-bently-nevada-series-10000-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}