{"product_id":"10020-1-2-honeywell-fail-safe-control-fsc-quad-processor-cpu-module","title":"10020\/1\/2 Honeywell Fail Safe Control (FSC) Quad Processor CPU Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell 10020\/1\/2 is a high-availability logic solver card specifically engineered for the Fail Safe Control (FSC) system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs a Quad Processor Module,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit utilizes a redundant internal architecture to execute safety-critical application programs,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that the Safety Instrumented System (SIS) remains deterministic and fault-tolerant.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis CPU module is the \"brain\" of the FSC rack,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eresponsible for scanning input states,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprocessing complex safety logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand commanding output actions in sub-millisecond timeframes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEven though the FSC series was officially discontinued at the end of 2018,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis brand-new 10020\/1\/2 unit provides essential lifecycle support for existing facilities,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for the maintenance of safety certifications without requiring a total system overhaul.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eCore Processing Logic and Hardware Metrics\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 10020\/1\/2 is built to meet the most stringent SIL (Safety Integrity Level) requirements,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efeaturing multi-layer self-diagnostics and high-speed internal bus communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Class:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eQuad-Redundant Processor \/ Main CPU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Environment:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell Fail Safe Control (FSC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnergy Requirements:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5 V DC @ 300 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcessing Architecture:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMulti-processor synchronization for 1oo2D or 2oo4D voting logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic Coverage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eContinuous hardware health checks with autonomous fault isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with FSC specialized I\/O and communication backplanes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHardware Resilience:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade shielding for high EMI\/RFI environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Mass:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e36 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCasing Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4 x 18.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 12.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCustoms Code:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHS 8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eSafety Applications and Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis Quad Processor Module is indispensable for high-risk industrial processes where logic failure is not an option.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmergency Shutdown (ESD):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eServing as the central logic solver for plant-wide shutdown sequences in oil refineries and offshore platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBurner Management Systems (BMS):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExecuting safe start-up and trip logic for large utility boilers and gas-fired furnaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFire and Gas (F\u0026amp;G) Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCoordinating the response between flame detectors and suppression systems in hazardous chemical storage areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Logic Solvers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperating in tandem with a secondary 10020\/1\/2 module to provide \"bumpless\" control transfer in high-availability safety racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy System Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReplacing aging processors in established FSC installations to eliminate memory parity errors and improve overall system diagnostic scores.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518926479533,"sku":"10020\/1\/2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-10020-1-2-quad-processor-module-sgafrsgcnkz.jpg?v=1766981950","url":"https:\/\/www.maxwellplc.com\/products\/10020-1-2-honeywell-fail-safe-control-fsc-quad-processor-cpu-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}