{"product_id":"07kt98-gjr5253100r3262-abb-programmable-logic-controller-advant-controller-31","title":"07KT98 GJR5253100R3262 ABB Programmable Logic Controller Advant Controller 31","description":"\u003cp\u003eThe \u003cb\u003eABB 07KT98 GJR5253100R3262\u003c\/b\u003e, also cataloged as the \u003cb\u003e07KT98\u003c\/b\u003e Programmable Logic Controller, operates as a dedicated hardware component for centralized real-time logic execution and integrated I\/O signal processing within CS31 system bus networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Configuration and Part Identification\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eABB 07KT98 GJR5253100R3262\u003c\/b\u003e serves as an integrated central processing unit incorporating discrete and analog interface channels:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e07KT98\u003c\/b\u003e: Model designation specifying the high-performance basic controller unit within the Advant Controller 31 Series 90 platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eGJR5253100R3262\u003c\/b\u003e: Specific factory order number for the hardware build containing onboard memory allocations and CS31 fieldbus connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCS31 Bus Interface\u003c\/b\u003e: Integrated network connection enabling system expansion via local or remote I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eI\/O Distribution\u003c\/b\u003e: 24 digital inputs, 16 transistor outputs, 8 configurable digital channels, 8 analog inputs, and 4 analog outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical and Physical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e07KT98 (GJR5253100R3262)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSWEDEN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable Logic Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per transistor output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e480 kB user program \/ 256 kB user data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 inputs (3 isolated groups of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 transistor outputs (2 isolated groups of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable Digital I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 channels (1 isolated group)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 channels (0-10 V, 0-20 mA, 4-20 mA, Pt100)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 channels (0-10 V, 0-20 mA, 4-20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnit Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 cm x 14.5 cm x 8.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 75 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNetwork Communication \u0026amp; Deterministic Processing\u003c\/h3\u003e\n\u003cp\u003eThe controller executes user programs and system tasks with high backplane bus communication velocity. Interfacing with higher-level control architectures via Profinet or EtherNet\/IP deterministic networks, the basic unit ensures low scan latency and continuous register updating. Memory expansion and program transfer are managed via SmartMedia Card slots (07 MC 90), while onboard firmware flash compatibility ensures synchronized system boot and stable execution across peripheral communication processors.\u003c\/p\u003e\n\u003ch3\u003ePackage Delivery Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB 07KT98 GJR5253100R3262 Basic Controller Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Protective anti-static enclosure bag\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Quick installation sheet and terminal map\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Mounting \u0026amp; Installation Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMounting Method\u003c\/b\u003e: Secure the unit onto a standard 35 mm DIN rail using the integrated snap-on locking feet, or panel-mount using screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSmartMedia Voltage Selection\u003c\/b\u003e: Use a 5 V SmartMedia card (07 MC 90) for standard units; 3.3 V cards require controller firmware V5.0 or higher.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eGrounding Requirements\u003c\/b\u003e: Connect the central ground terminal directly to the enclosure backplate with low-impedance copper wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSignal Cable Isolation\u003c\/b\u003e: Separate low-voltage analog signal lines (0-10 V, 4-20 mA, Pt100) from 24 VDC transistor switching wiring and AC power mains.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage is required to power the 07KT98 GJR5253100R3262 controller?\u003c\/p\u003e\n\u003cp\u003eThe unit operates on a standard 24 VDC nominal power supply connected to the main supply terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich signal types are supported on the 8 analog input channels?\u003c\/p\u003e\n\u003cp\u003eEach analog input can be individually configured for 0-10 V, 0-20 mA, 4-20 mA, or Pt100 RTD sensor inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat memory sizes are available on the 07KT98 GJR5253100R3262 base model?\u003c\/p\u003e\n\u003cp\u003eThe controller integrates 480 kB of user program memory alongside 256 kB of dedicated user data storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the digital input and output channels electrically isolated?\u003c\/p\u003e\n\u003cp\u003eYes. Digital inputs and transistor outputs are isolated from internal logic in distinct groups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat SmartMedia card voltage must be used for program transfer?\u003c\/p\u003e\n\u003cp\u003eStandard units require 5 V SmartMedia cards (07 MC 90); 3.3 V cards are compatible only with firmware V5.0 or above.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the controller mounted inside an automation panel?\u003c\/p\u003e\n\u003cp\u003eThe basic unit features a snap-on mechanism for direct mounting onto 35 mm steel DIN rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan external communication modules be connected to the 07KT98?\u003c\/p\u003e\n\u003cp\u003eYes. The basic unit can be expanded using communication processors like the 07 KP 90 via the system bus interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current rating do the onboard transistor outputs support?\u003c\/p\u003e\n\u003cp\u003eThe solid-state digital transistor outputs are rated for a maximum continuous current of 0.5 A per channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021148049581,"sku":"GJR5253100R3262","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_07kt98_gjr5253100r3262_1.jpg?v=1788358246","url":"https:\/\/www.maxwellplc.com\/products\/07kt98-gjr5253100r3262-abb-programmable-logic-controller-advant-controller-31","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}