Yokogawa EB501-10 ER Bus Interface Slave Module
-
Dimensions: 25 x 15 x 10 cm
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The Yokogawa EB501-10 is an ER Bus Interface Slave Module installed in a remote node of a Yokogawa Field Network I/O (FIO) system. It communicates with an EB401 ER Bus Interface Master Module in the local node or Field Control Unit, providing the ER Bus connection between the control station and remote I/O node.
Model Configuration
- EB501: ER Bus Interface Slave Module for installation in a remote node.
- -10: Complete model code supplied for this product.
The supplied model-code interpretation identifies the -1 portion as the standard type without explosion protection and 0 as the basic type. These suffix meanings should be checked against the ordering-code documentation for the exact hardware revision before procurement.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | EB501-10 |
| Brand | Yokogawa |
| Product Type | ER Bus Interface Slave Module |
| System | Yokogawa FIO / CENTUM DCS |
| Bus Function | ER Bus slave interface for remote nodes |
| Physical Layer Interface | IEEE 802.3 10BASE-2 |
| Communication Port | 1 coaxial port |
| Connector | BNC coaxial connector |
| Communication Speed | 10 Mbps |
| Maximum Transmission Distance | 185 m per segment with specified YCB141 cable |
| Current Consumption | 0.7 A, as supplied; confirm against the exact module documentation |
| Weight | Approx. 0.3 kg, as supplied |
ER Bus Communication and Remote Node Function
The EB501 operates on the remote-node side of the Yokogawa ER Bus architecture. It communicates with an EB401 master module installed in a local node or supported Field Control Unit.
The module provides one 10BASE-2 coaxial interface. Its BNC connection forms part of the ER Bus link between the local and remote nodes.
For a dual-redundant bus arrangement, two EB501 modules can be installed in the remote node. Each module serves a separate bus path, subject to the system configuration and applicable Yokogawa installation requirements.
Installation and Electrical Integration
The EB501 is designed for installation in a compatible ER Bus Node Unit, including the ANR10S and ANR10D node configurations.
Before installation, verify the following:
- Confirm that the node unit supports the EB501 module and the intended system configuration.
- Check the module model code and hardware revision against the system configuration records.
- Use the specified coaxial cable and compatible BNC connections for the ER Bus.
- For 10BASE-2 cabling, follow the system's documented bus topology and termination requirements.
- In dual-redundant configurations, keep the two bus paths correctly identified and separated as required by the installation design.
- Isolate equipment as required by the applicable maintenance procedure before inserting, removing, or wiring modules.
Do not infer hot-swap capability from the module's plug-in form factor. Follow the Yokogawa hardware and maintenance instructions for the specific node unit.
Frequently Asked Questions
- Q: What is the function of the Yokogawa EB501-10?
A: It is an ER Bus Interface Slave Module installed in a remote node to communicate with an EB401 master module on the local-node side.
- Q: Which module communicates with the EB501?
A: The EB501 communicates with the EB401 ER Bus Interface Master Module installed in a compatible local node or Field Control Unit.
- Q: What communication interface does the EB501 use?
A: The EB501 uses a 10BASE-2 coaxial interface with a BNC connector.
- Q: How many communication ports are provided?
A: The EB501 has one ER Bus coaxial port. Dual-redundant operation uses two EB501 modules.
- Q: Can the EB501 be used in an ANR10D node?
A: Yokogawa documentation identifies the EB501 as the ER Bus slave module for remote nodes, including ANR10S and ANR10D configurations.
- Q: What cable is used for the ER Bus connection?
A: The supplied information identifies YCB141 coaxial cable. Confirm cable and termination requirements against the applicable Yokogawa system documentation.
- Q: Does the EB501 support dual-redundant communication?
A: Yes. Yokogawa documentation describes dual-redundant ER Bus operation using two EB501 modules in the remote node.
- Q: Can the EB501 be installed in place of an EB401?
A: No. The EB501 is the remote-node slave interface, while the EB401 is the local-node master interface. They have different system roles.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.