{"product_id":"snat7640-3bse003195r1-abb-controller-card-acs500","title":"SNAT7640 3BSE003195R1 ABB Controller Card ACS500","description":"\u003cp\u003eThe \u003cstrong\u003eABB SNAT7640 3BSE003195R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSNAT7640\u003c\/strong\u003e Controller Card, operates as a dedicated hardware component for keyboard interface management and control signal processing within ABB ACS500 drive platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Designation \u0026amp; Variant Overview\u003c\/h3\u003e\n\u003cp\u003eThe SNAT7640 printed circuit board manages local operator keypad interaction and system bus signals. Identification parameters comprise:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHardware Model: SNAT7640\u003c\/li\u003e\n\u003cli\u003eOrderable Spare Part Number: 3BSE003195R1\u003c\/li\u003e\n\u003cli\u003eFunctional Type: Keyboard Interface PC Board \u0026amp; Drive Controller Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSNAT7640 3BSE003195R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.3 x 18.3 x 2.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Protocol\u003c\/td\u003e\n\u003ctd\u003eProfibus-DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 k to 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Interface\u003c\/td\u003e\n\u003ctd\u003e9-pin Sub-D female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003e4 kV lightning surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e9 to 36 VDC redundant input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDispatch Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Bus \u0026amp; Protocol Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe SNAT7640 controller card incorporates high-speed backplane bus communication velocity Licences and fieldbus conversion circuitry to support Profibus-DP communication up to 12 Mbit\/s. Embedded logic maintains strict firmware flash compatibility across drive backplanes, enabling deterministic networks integration with Profinet \/ EtherNet\/IP topologies and real-time execution of operator control commands.\u003c\/p\u003e\n\u003ch3\u003eFactory Shipment Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB SNAT7640 3BSE003195R1 Controller Card\u003c\/li\u003e\n\u003cli\u003e1 x Sub-D Connector Interface Hardware Kit\u003c\/li\u003e\n\u003cli\u003e1 x Conductive Anti-Static Packaging Sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAssembly \u0026amp; Wiring Instructions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Power Shutdown\n\u003cul\u003e\n\u003cli\u003eDisconnect redundant 9-36 VDC auxiliary power sources and main drive voltage supplies prior to servicing the card.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStatic Control Protocols\n\u003cul\u003e\n\u003cli\u003eWear a grounded wrist strap when handling the board to protect sensitive processor logic from electrostatic discharge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhysical Mount Fastening\n\u003cul\u003e\n\u003cli\u003eAlign board edges with guide slots and secure mounting standoffs firmly to maintain chassis grounding continuity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFieldbus Cable Routing\n\u003cul\u003e\n\u003cli\u003eUtilize shielded twisted-pair cables terminated at the 9-pin Sub-D female port, maintaining 200 mm clearance from power leads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What input auxiliary voltage range does the SNAT7640 controller card require?\u003c\/p\u003e\n\u003cp\u003eA: The card accepts a wide redundant DC power supply input ranging from 9 VDC to 36 VDC while drawing less than 3 W total power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What communication protocols and maximum baud rates are supported on board?\u003c\/p\u003e\n\u003cp\u003eA: The board supports Profibus-DP network communication over a standard 9-pin Sub-D female interface with baud rates up to 12 Mbit\/s.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is hot-swapping permitted during drive operation?\u003c\/p\u003e\n\u003cp\u003eA: No, control power must be completely isolated before inserting or removing the card to prevent electrical stress on logic channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What transient surge and electrical isolation protections are built into the board?\u003c\/p\u003e\n\u003cp\u003eA: The card features 1500 VDC power isolation along with integrated 4 kV lightning surge suppression circuits on input lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does firmware flash compatibility impact drive replacement?\u003c\/p\u003e\n\u003cp\u003eA: Matching firmware revisions guarantees correct fieldbus memory mapping and maintains consistent task timing across the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What are the physical transport package dimensions and total item weight?\u003c\/p\u003e\n\u003cp\u003eA: The unit weighs 0.35 kg with packaged shipping box dimensions measuring 22.3 cm in length, 18.3 cm in width, and 2.3 cm in height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What operating ambient thermal limits must be observed?\u003c\/p\u003e\n\u003cp\u003eA: Enclosure operating temperatures must be maintained between -10 deg C and +55 deg C under non-condensing relative humidity conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How should fieldbus communication shields be terminated on this module?\u003c\/p\u003e\n\u003cp\u003eA: Bus cable shields must be clamped 360 degrees to the enclosure grounding plate at the cabinet entry point for noise rejection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021139955885,"sku":"SNAT7640 3BSE003195R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/snat7640_1.jpg?v=1792039401","url":"https:\/\/www.maxwellplc.com\/ga\/products\/snat7640-3bse003195r1-abb-controller-card-acs500","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}