{"product_id":"pm564-rp-eth-ac-1sap121100r0071-abb-programmable-logic-controller-ac500-eco","title":"PM564-RP-ETH-AC 1SAP121100R0071 ABB Programmable Logic Controller AC500-eCo","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB PM564-RP-ETH-AC 1SAP121100R0071\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePM564-RP-ETH-AC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable Logic Controller, operates as a dedicated hardware component for logic execution and process control within industrial automation architectures. Configured for I\/O signal management, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB PM564-RP-ETH-AC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003ePM564-RP-ETH-AC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable Logic Controller) provides direct electrical interface for 6 digital inputs, 6 digital outputs, 2 analog inputs, and 1 analog output. The unit serves as the primary processing node for CoDeSys-based automation platforms, facilitating program execution and data routing via integrated Ethernet connectivity.\u003c\/p\u003e\n\u003ch3\u003eSuffix Designation\u003c\/h3\u003e\n\u003cp\u003eThe PM564-RP-ETH-AC (1SAP121100R0071) is a standardized CPU unit within the AC500-eCo series. The \"RP\" designation indicates the relay output capability, while the \"ETH\" suffix denotes the inclusion of the integrated Ethernet interface for programming and data communication.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePM564-RP-ETH-AC (1SAP121100R0071)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.5 x 7.5 x 7.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115–230 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 kB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Inputs \/ 6 Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Inputs \/ 1 Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunication \u0026amp; System Architecture\u003c\/h3\u003e\n\u003cp\u003eThe PM564-RP-ETH-AC supports backplane bus communication velocity sufficient for the AC500-eCo platform. It maintains firmware flash compatibility with S500 and S500-eCo I\/O expansion modules, allowing for I\/O density scaling based on application demands. The unit utilizes an Ethernet router service for networked automation tasks, enabling deterministic data propagation. It is designed to handle control sequences within the CoDeSys environment while ensuring data integrity across the internal communication bus.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePM564-RP-ETH-AC CPU unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal connection blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgramming\/Firmware update documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard protective packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Secure a low-impedance ground connection to the cabinet functional earth rail to maintain signal integrity for the analog I\/O channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring: Ensure AC supply lines are routed separately from low-voltage signal cables to minimize cross-talk and electrical noise induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Utilize shielded twisted-pair cables for all analog inputs and Ethernet connections, terminating shields at the cabinet entry point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane insertion: Align the expansion bus connector with the mating AC500 I\/O module before securing the unit to the DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental: Operate within an enclosure rated for the local environment to prevent exposure to dust, conductive particulates, or excess humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this controller support hot-swap behavior?\u003c\/p\u003e\n\u003cp\u003eA: No, the unit does not support hot-swapping; power must be completely isolated from the PLC and expansion modules before any hardware adjustment or replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the controller affect backplane load?\u003c\/p\u003e\n\u003cp\u003eA: Internal logic consumes a fixed amount of current from the power supply; verify the total power budget of the configuration before adding I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is there a redundancy switching delay?\u003c\/p\u003e\n\u003cp\u003eA: Redundancy is not native to this hardware configuration; any failover switching must be managed via higher-level system architecture and software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is firmware compatibility maintained?\u003c\/p\u003e\n\u003cp\u003eA: Firmware is managed through the programming software and can be deployed via the integrated SD card interface or the Ethernet port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the unit provide signal isolation?\u003c\/p\u003e\n\u003cp\u003eA: The PLC features internal isolation between the power supply and I\/O logic circuits; refer to the datasheet for specific voltage withstand levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are there field wiring constraints for the analog inputs?\u003c\/p\u003e\n\u003cp\u003eA: Keep analog wiring runs as short as possible and utilize shielded cabling to ensure accuracy and prevent signal drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is program status monitored?\u003c\/p\u003e\n\u003cp\u003eA: Operation status and program execution metrics are available via the CoDeSys programming interface and front-panel status LEDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the unit be integrated into a DCS environment?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is designed for integration into distributed control networks via its integrated Ethernet router capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231181791405,"sku":"1SAP121100R0071","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-pm564-rp-eth-ac-1sap121100r0071-programmable-logic-controller-0rtgvrzsxyo_d81d1137-0481-43d0-a858-01881996ada0.jpg?v=1762942347","url":"https:\/\/www.maxwellplc.com\/ga\/products\/pm564-rp-eth-ac-1sap121100r0071-abb-programmable-logic-controller-ac500-eco","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}