Omron V680-HS52-R Cylindrical Antenna V680 Series
-
Dimensions: M22 x 65 mm (Housing)
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for high-frequency inductive RFID read/write operations in industrial tracking networks, the Omron V680-HS52-R (V680-HS52 Cylindrical Antenna) provides direct physical/electrical execution.
Model Designation & Feature Matrix
- V680: Industrial RFID System Architecture Platform
- HS: High-Sensitivity Electromagnetic Field Read/Write Antenna Head
- 52: M22 Threaded Cylindrical Housing (65 mm Overall Length)
- R: Flexible Robotic Cable Assembly with Non-Waterproof Interface Connector
Technical Specifications Summary
| Parameter | Specification |
|---|---|
| Model | V680-HS52-R |
| Brand | Omron |
| Origin | Japan |
| Weight | 0.85 kg (Net) |
| Shipping Weight | 2.0 kg |
| Shipping Dimensions | M22 x 65 mm (Housing) |
| Operating Temp | -10 to 60 deg C (No icing) |
| Power Consumption | Powered via V680 Controller |
| Insulation Resistance | 20 MOhm min. (at 500 VDC) |
| Shock Resistance | 500 m/s2 (X, Y, Z directions 3 times each) |
| Vibration Resistance | 10 to 500 Hz, 1.5-mm double amplitude at 100 m/s2 acceleration |
| Degree of Protection | IP67 (IEC 60529) / Oil-resistance equivalent to IP67G (JIS C 0920) |
| Cable Type | Flexible cable, non-waterproof connector |
Deterministic Network Bus & Firmware Flash Execution
The antenna transducer transfers high-frequency magnetic flux field signals directly to host controllers via deterministic industrial buses. Internal controller firmware flash compatibility protocols verify antenna resonance feedback and transmission framing parameters on system startup, ensuring deterministic packet transfers without introducing backplane latency across PLC interface racks.
Standard Delivery Contents
- 1 x Omron V680-HS52-R Cylindrical RFID Antenna Unit
- 2 x M22 Lock Nuts for Panel/Bracket Mounting
- 1 x Mounting Instruction Sheet
Physical Installation & Cable Routing Directives
- Mount the M22 threaded barrel into a pre-drilled bracket hole using supplied lock nuts, maintaining recommended clear space around metallic objects to prevent RF detuning.
- Secure the flexible robotic cable along moving machine axis links, ensuring the bending radius remains within specified mechanical limits to eliminate conductor fatigue.
- Ground the connected V680 controller shield terminal to a low-impedance copper earth bus to prevent high-frequency noise interference.
- Avoid routing the non-waterproof connector end through locations exposed to direct liquid spray or oil accumulation.
Frequently Asked Questions
-
What physical dimensions are specified for the antenna barrel thread?
The antenna features an M22 threaded outer barrel with a total housing length of 65 mm for standard clearance hole or bracket mounting.
-
What degree of environmental protection applies to the antenna portion?
The antenna head meets IP67 (IEC 60529) water ingress protection and oil-resistance equivalent to IP67G (JIS C 0920, Appendix 1).
-
Is the cable connector end sealed against liquid immersion?
No, the unit features a flexible robotic cable terminated with a non-waterproof connector, requiring enclosure protection at the connection point.
-
What insulation resistance value is verified during factory testing?
The unit provides an insulation resistance of 20 MOhm minimum at 500 VDC between the internal cable terminals and the metallic outer case.
-
How does the antenna handle mechanical shock in high-vibration applications?
The housing withstands shock loads up to 500 m/s2 applied 3 times each across X, Y, and Z axes (18 impacts total).
-
How does controller firmware flash compatibility affect antenna field operation?
The host controller firmware validates antenna tuning characteristics during start sequences to prevent communication errors during tag reads.
-
What operational temperature limits must be maintained during active tag scanning?
The ambient operating temperature range is -10 deg C to 60 deg C, provided no ice formation occurs on the antenna head.
-
How should cable shielding be configured to prevent RF interference?
Ensure the cable shield grounds directly through the mating V680 controller unit to eliminate ground loops and field distortion.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.