{"product_id":"omron-nx701-1700-motion-controller-nx7-series","title":"Omron NX701-1700 Motion Controller NX7 Series","description":"\u003cp\u003eConfigured for high-speed multi-axis motion synchronization and OPC-UA execution in industrial automation networks, the \u003cstrong\u003eOmron NX701-1700\u003c\/strong\u003e (\u003cstrong\u003eNX701-1700\u003c\/strong\u003e Motion Controller) provides direct physical and electrical execution across high-performance control architectures.\u003c\/p\u003e\n\u003ch3\u003eArchitecture Coding \u0026amp; Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe product part number designates precise processing tiers, axis counts, and embedded protocol capabilities within the Omron Sysmac automation platform.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX701\u003c\/strong\u003e: High-performance dual-core CPU processing architecture designed for demanding real-time control applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e17\u003c\/strong\u003e: Maximum motion profile control capability supporting up to 256 real-time axes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Integrated EtherCAT master connectivity with OPC-UA server communication functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX701-1700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.88 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e25 cm x 20 cm x 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Task Cycle Time\u003c\/td\u003e\n\u003ctd\u003e0.125 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e80 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariables Memory\u003c\/td\u003e\n\u003ctd\u003e260 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronous Axes\u003c\/td\u003e\n\u003ctd\u003e256 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Axes\u003c\/td\u003e\n\u003ctd\u003e256 max. (including virtual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe controller executes high-speed task loops utilizing direct EtherNet\/IP deterministic networks alongside EtherCAT master capabilities. Internal backplane bus communication velocity delivers synchronized data exchange across modular expansion units without perceptible latency. Upgraded firmware flash compatibility permits continuous system updates without risking persistent memory loss, while I\/O density scaling allows seamless expansion across complex multi-axis motion networks.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX701-1700 Motion Controller\u003c\/li\u003e\n\u003cli\u003e1 x Terminal block assembly for power line entry\u003c\/li\u003e\n\u003cli\u003e1 x Protective bus end cover unit\u003c\/li\u003e\n\u003cli\u003e1 x Hardware installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnclosure Mounting \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Placement\n\u003cul\u003e\n\u003cli\u003eLock the controller onto a heavy-duty 35 mm DIN rail within a steel enclosure, ensuring a vertical orientation for unimpeded air convection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Network Cabling\n\u003cul\u003e\n\u003cli\u003eConnect high-speed EtherCAT loops using category 5e or higher shielded twisted-pair cables to eliminate electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eGrounding Terminal Attachment\n\u003cul\u003e\n\u003cli\u003eAttach a low-impedance conductor directly from the ground lug to the cabinet earth bar to prevent electrostatic discharge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eConnector Port Sealing\n\u003cul\u003e\n\u003cli\u003eInstall protective dust covers over unused Ethernet ports to prevent dust contamination in harsh operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Operation Frequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the minimum cycle time for the primary execution task?\u003c\/p\u003e\n\u003cp\u003eThe processing core executes the primary control loop at a minimum cycle time of 0.125 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many total synchronous axes can this hardware execute?\u003c\/p\u003e\n\u003cp\u003eThe module manages up to 256 real-time synchronized axes, including physical and virtual configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat memory allocations are provided for code and system data?\u003c\/p\u003e\n\u003cp\u003eThe controller features 80 MB of non-volatile program memory and 260 MB dedicated to variable storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich embedded protocols are available on the physical ports?\u003c\/p\u003e\n\u003cp\u003eIntegrated communication options include OPC-UA, EtherCAT Master, EtherNet\/IP, and standard TCP\/IP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the net weight of the controller module?\u003c\/p\u003e\n\u003cp\u003eThe standalone unit weighs 0.88 Kg, with a total packaged shipping weight of 3 Kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit interface with local expansion modules?\u003c\/p\u003e\n\u003cp\u003eLocal expansion signals route through the proprietary high-speed NX I\/O bus interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environment operating temperature range must be maintained?\u003c\/p\u003e\n\u003cp\u003eThe surrounding ambient temperature inside the panel must stay within 0 deg C and 55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the controller support direct OPC-UA client connection?\u003c\/p\u003e\n\u003cp\u003eYes, embedded OPC-UA server functionality allows direct industrial network database connectivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306640097453,"sku":"NX701-1700","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx701-1700.jpg?v=1791554311","url":"https:\/\/www.maxwellplc.com\/ga\/products\/omron-nx701-1700-motion-controller-nx7-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}