{"product_id":"omron-ns5-sq10-ecv2-interactive-display-panel-ns-series","title":"Omron NS5-SQ10-ECV2 Interactive Display Panel NS Series","description":"\u003cp data-path-to-node=\"4\"\u003eConfigured for direct operator interface control and real-time process visualization in Ethernet and serial control networks, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"130\"\u003eOmron NS5-SQ10-ECV2\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"151\"\u003eNS5-SQ10\u003c\/b\u003e Interactive Display Panel) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eModel Nomenclature and Structure\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eNS5\u003c\/b\u003e: Product series identifier designating 5.7-inch screen size class.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSQ\u003c\/b\u003e: Display technology variant specifying STN color LCD panel architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003e10\u003c\/b\u003e: Hardware iteration and display resolution standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eECV2\u003c\/b\u003e: Enhanced communication feature set, version 2 hardware revision with integrated system memory enhancements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eSystem Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNS5-SQ10-ECV2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e220 mm x 170 mm x 90 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e-20 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e15 W max.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e24 VDC (20.4 to 27.6 VDC permissible range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eBattery Life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e5 years at 25 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eOperating Environment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003eFree from corrosive gases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eAccessory Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003eInteractive Display Panel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eNetwork Determinism and Firmware Interface\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe terminal manages real-time status updates across controller networks through dedicated memory link functions and high-speed communication buffers. Protocol handling operates with minimal latency when mapped to PLC data areas, preventing network bottlenecks during large block data transfers. Internal flash memory stability guarantees firmware flash compatibility and uninterrupted boot sequences during industrial power cycle events. High-density I\/O registers ensure deterministic screen transition times and reliable touch-coordinate processing under continuous continuous bus communication operations.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NS5-SQ10-ECV2 Interactive Display Panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Power Supply Connector Block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e4 x Mounting Clamps and Screws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e1 x Watertight Panel Gasket (Pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003ePanel Mounting and Wiring Protocol\u003c\/h3\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eCabinet Cutout Preparation\u003c\/h4\u003e\n\u003cp data-path-to-node=\"15\"\u003ePrepare a clean rectangular opening in the enclosure door according to panel tolerances. Ensure surrounding clearance measures at least 100 mm to allow adequate convection cooling and cable strain relief.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"16\"\u003eGasket and Clamp Engagement\u003c\/h4\u003e\n\u003cp data-path-to-node=\"17\"\u003eVerify that the perimeter rubber sealing gasket is seated properly in the bezel channel. Insert the unit into the cutout and secure all four mounting brackets evenly, applying targeted torque to prevent panel distortion while maintaining IP65\/NEMA 4X front sealing integrity.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"18\"\u003ePower Supply Grounding\u003c\/h4\u003e\n\u003cp data-path-to-node=\"19\"\u003eConnect a dedicated 24 VDC power feed directly to the terminal screw block using shielded twisted pair wire (16 to 14 AWG). Terminate the functional ground (FG) terminal to the central enclosure earth point using the shortest possible low-impedance conductor to suppress high-frequency noise.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eTechnical Clarifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"21\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,0,0\"\u003eIs hot-swapping supported during live controller operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"21,0,0\"\u003eDisconnecting communication cables while live is safe, but removing the primary 24 VDC power connector during operation causes immediate display termination and potential unwritten memory log corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,1,0\"\u003eWhat causes screen flicker or unresponsiveness during touch entry?\u003c\/p\u003e\n\u003cp data-path-to-node=\"21,1,0\"\u003eTransient noise on the 24 VDC supply line or an ungrounded FG terminal disrupts touch screen controller calibration. Verify clean DC power and low-impedance earth grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,2,0\"\u003eHow does the internal battery backup preserve system data?\u003c\/p\u003e\n\u003cp data-path-to-node=\"21,2,0\"\u003eThe integrated 5-year lithium battery maintains real-time clock tracking and alarm history logs stored in non-volatile SRAM when main 24 VDC external power is removed from the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,3,0\"\u003eCan the terminal operate in environments with chemical airborne contaminants?\u003c\/p\u003e\n\u003cp data-path-to-node=\"21,3,0\"\u003eThe unit must be deployed strictly in locations free from corrosive gases, aggressive solvents, and conductive dust to prevent internal PCB traces and display matrix degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,4,0\"\u003eWhat is the recommended power cable sizing and fusing protection?\u003c\/p\u003e\n\u003cp data-path-to-node=\"21,4,0\"\u003eUse 1.5 mm2 (16 AWG) copper wire rated for 75 deg C or higher. Install a fast-acting 2 A inline fuse on the +24 VDC positive terminal rail to protect internal power components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,5,0\"\u003eHow are communication protocol timeouts handled across serial links?\u003c\/p\u003e\n\u003cp data-path-to-node=\"21,5,0\"\u003eCommunication timeouts prompt visual system alarm flags on the display layer. Response retry counts and interval delays are configurable inside the system menu interface settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,6,0\"\u003eWhat are the physical mounting orientation limitations for heat dissipation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"21,6,0\"\u003eThe display panel must be mounted vertically (within 30 deg of perpendicular) to enable vertical heat convection through top and bottom rear casing ventilation slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,7,0\"\u003eWhat firmware updating precautions must be taken during system maintenance?\u003c\/p\u003e\n\u003cp data-path-to-node=\"21,7,0\"\u003eEnsure uninterrupted 24 VDC power delivery throughout the entire memory transfer cycle. Power interruptions during flash memory writes corrupt boot sectors and require hardware replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306651304109,"sku":"NS5-SQ10-ECV2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NS-4.jpg?v=1790141007","url":"https:\/\/www.maxwellplc.com\/ga\/products\/omron-ns5-sq10-ecv2-interactive-display-panel-ns-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}