Omron G9SX-ADA222-T150-RC Flexible Safety Unit Advanced Unit
Omron G9SX-ADA222-T150-RC Flexible Safety Unit Advanced Unit
Omron

Omron G9SX-ADA222-T150-RC Flexible Safety Unit Advanced Unit

SKU: G9SX-ADA222-T150-RC
Categories : All Products
In Stock
  • Dimensions: 115 mm x 35 mm x 125 mm
  • Country of origin: Japan
  • Payment: T/T, Western Union
  • Shipping port: Xiamen
1 years warranty
Delivery time: 3-7 business days
Free 30 days return

Help

If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, withing 24 hours on weekdays.

Customer service

All questions about your order, return and delivery must be sent to our customer service team by e-mail at yourstore@yourdomain.com

Sale & Press

If you are interested in selling our products, need more information about our brand or wish to make a collaboration, please contact us at press@yourdomain.com

The Omron G9SX-ADA222-T150-RC, also cataloged as the G9SX-ADA222 Flexible Safety Unit, operates as a dedicated hardware component for safety input evaluation and timed safety output execution within G9SX platform control systems.

Model Suffix & Configuration Structure

  • G9SX: Base platform family for flexible logic safety modules
  • ADA: Advanced unit logic architecture
  • 2: 2 instantaneous safety outputs
  • 2: 2 OFF-delayed safety outputs
  • 2: 2 auxiliary signal outputs
  • T150: Adjustable OFF-delay timer parameter up to 150 s max.
  • RC: Spring-cage terminal block terminal interface

Technical Hardware Specifications

Parameter Specification
Model G9SX-ADA222-T150-RC
Brand Omron
Origin Japan
Weight 0.2 kg
Shipping Dimensions 115 mm x 35 mm x 125 mm
Operating Temp -10 to 55 deg C
Power Consumption 4 W max.
Rated Supply Voltage 24 VDC
Operating Voltage Range -15% to 10% of rated supply voltage
Safety Input Voltage 20.4 VDC to 26.4 VDC
Safety Input Impedance Approx. 2.8 k-ohm
Instantaneous / OFF-Delayed Output Type P-channel MOS FET transistor output
Output Load Current (<= 2 outputs) 1.0 A DC max.
Output Load Current (>= 3 outputs) 0.8 A DC max.
Auxiliary Output Type PNP transistor output
Auxiliary Output Load Current 100 mA max.
Vibration Resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)

Industrial Network & High-Density I/O Scaling Architecture

The module utilizes solid-state P-channel MOS FET switching output stages to handle safety circuits without mechanical contact degradation. Communication backplane bus linkages enable expansion module scaling and logical cross-channel linkage across Profinet and EtherNet/IP deterministic networks via associated gateway adapters. Strict firmware flash compatibility ensures synchronized timing loops and consistent I/O processing across expanded multi-unit safety configurations.

Scope of Delivery & Package Assembly

  • 1 x Omron G9SX-ADA222-T150-RC Flexible Safety Logic Controller
  • 1 x Pre-assembled Spring-Cage Terminal Block Set
  • 1 x Operating Instructions & Installation Safety Manual

Panel Mounting & Wiring Protocols

  • Rail Installation

    Securely latch the module onto a standard 35-mm DIN rail within an enclosure meeting an IP54 protection standard. Maintain 50-mm clearance above and below the housing for free air convection.

  • Spring-Cage Terminal Termination

    Strip field wiring conductors to specified strip length before inserting into the spring-cage terminals. Ensure secure conductor clamping without exposing bare copper strand sections.

  • Loop Noise Isolation

    Keep safety input wiring and transistor output drive lines separate from high-voltage motor cables, inverter outputs, and inductive switching noise sources.

Engineering Technical Inquiries

  • What output types are used for the main safety circuits on this model?

    The unit utilizes P-channel MOS FET transistor outputs for both instantaneous and OFF-delayed safety output channels.

  • What is the maximum selectable delay timing on the T150 model variant?

    The T150 designation supports configurable OFF-delay timing intervals up to a maximum duration of 150 s.

  • How does total active output count impact output load current capacity?

    When operating 2 or fewer outputs, maximum load current is 1 A DC per output; with 3 or more outputs active, capacity limits to 0.8 A DC per output.

  • What terminal mechanism is provided on the -RC suffix model?

    The -RC suffix denotes removable spring-cage terminal blocks designed for vibration-resistant toolless field wire insertion.

  • What is the input impedance rating of the safety input evaluation channels?

    The safety input channels operate with an internal impedance of approximately 2.8 k-ohm over an operating range of 20.4 VDC to 26.4 VDC.

  • Can the auxiliary output drive heavy load relays directly?

    No, the PNP auxiliary output is rated for a maximum load current of 100 mA and is intended exclusively for status monitoring signals.

  • Is hot-swapping permitted while 24 VDC power is applied?

    No, main DC control power must be completely disconnected before removing or wiring spring-cage terminal blocks and expansion bus connectors.

  • What power consumption limit applies to the G9SX-ADA222-T150-RC?

    The internal processing circuitry and output driver stages consume a maximum power rating of 4 W under 24 VDC supply voltage.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


PDF Datasheet Official Technical Specifications

Omron G9SX-ADA222-T150-RC Flexible Safety Unit Advanced Unit

You may also like

From our blog

Latest News and Insights

Goldwind Launches Clean Energy Smart Operation Overall Solution
Oct 04, 2026
Maxwell
Goldwind Launches Clean Energy Smart Operation Overall Solution
Goldwind Technology, one of the world's leading wind turbine manufacturers, has unveiled its comprehensive clean...
Read More
Tianze Zhilian Releases Wind Farm Safety AI Solution with Mobile Intelligent Inspection
Oct 04, 2026
Maxwell
Tianze Zhilian Releases Wind Farm Safety AI Solution with Mobile Intelligent Inspection
Chinese technology company Tianze Zhilian has launched a comprehensive artificial intelligence solution for wind farm...
Read More
Cadeler and Vattenfall Partner on Offshore Wind Maintenance Solutions
Oct 03, 2026
Maxwell
Cadeler and Vattenfall Partner on Offshore Wind Maintenance Solutions
Cadeler and Vattenfall Partner on Offshore Wind Maintenance Solutions Offshore wind installation specialist Cadeler and...
Read More
Huaneng New Energy Patents Intelligent Robot Safety Collaborative Control Technology
Oct 03, 2026
Maxwell
Huaneng New Energy Patents Intelligent Robot Safety Collaborative Control Technology
Huaneng New Energy Patents Intelligent Robot Safety Collaborative Control Technology China's push toward autonomous operations...
Read More
COPA-DATA Showcases Unified Wind Farm SCADA at WindEnergy Hamburg 2026
Oct 02, 2026
Maxwell
COPA-DATA Showcases Unified Wind Farm SCADA at WindEnergy Hamburg 2026
COPA-DATA Showcases Unified Wind Farm SCADA at WindEnergy Hamburg 2026 Austrian automation software provider COPA-DATA...
Read More
Yangjiang Offshore Wind Power Installed Capacity Exceeds 8GW Ranking First in China
Oct 02, 2026
Maxwell
Yangjiang Offshore Wind Power Installed Capacity Exceeds 8GW Ranking First in China
Yangjiang Offshore Wind Power Installed Capacity Exceeds 8GW Ranking First in China China's offshore wind...
Read More
2026 World Manufacturing Conference Concludes in Hefei with 1200 Exhibitors
Oct 01, 2026
Maxwell
2026 World Manufacturing Conference Concludes in Hefei with 1200 Exhibitors
The 2026 World Manufacturing Conference, one of China's premier industrial technology showcases, concluded on September...
Read More
Dongfeng Motor Humanoid Robot Xiao Dong to Enter Factory Trial Production in October
Oct 01, 2026
Maxwell
Dongfeng Motor Humanoid Robot Xiao Dong to Enter Factory Trial Production in October
China's state-owned automotive giant is preparing to deploy its homegrown humanoid robot on the factory...
Read More
Wind Turbine Prices Stabilize as Industry Profit Inflection Point Approaches
Sep 30, 2026
Maxwell
Wind Turbine Prices Stabilize as Industry Profit Inflection Point Approaches
After years of relentless price erosion that has squeezed margins across the wind energy supply...
Read More
Chengdu Launches Embodied Intelligence Pilot Base for Automotive Manufacturing
Sep 30, 2026
Maxwell
Chengdu Launches Embodied Intelligence Pilot Base for Automotive Manufacturing
The convergence of embodied intelligence and automotive manufacturing took a significant step forward on September...
Read More