{"product_id":"omron-cp1l-m60dr-a-cp1l-series-programmable-controller","title":"Omron CP1L-M60DR-A CP1L Series Programmable Controller","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CP1L-M60DR-A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP1L-M60DR-A\u003c\/strong\u003e High Performing Programmable Controller with Embedded Ethernet, operates as a dedicated hardware component for localized sequential logic control and automated system execution within CP-series architecture platforms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model Code:\u003c\/strong\u003e CP1L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Category (M):\u003c\/strong\u003e Monolithic CPU Unit with high-capacity memory (10K steps) and extended I\/O expansion capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Capacity (60):\u003c\/strong\u003e 60 total built-in I\/O points (36 discrete inputs, 24 relay outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type (R):\u003c\/strong\u003e Electromechanical Relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Type (A):\u003c\/strong\u003e 100 to 240 VAC wide-range power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1L-M60DR-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.5 cm x 11.0 cm x 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 cm x 14.0 cm x 11.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 VA max. at 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eStored program method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Control Method\u003c\/td\u003e\n\u003ctd\u003eCyclic scan with immediate refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in I\/O Points\u003c\/td\u003e\n\u003ctd\u003e60 points (36 Inputs, 24 Outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Expandable I\/O\u003c\/td\u003e\n\u003ctd\u003e180 points (using up to 3 CP-series expansion units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Time\u003c\/td\u003e\n\u003ctd\u003eBasic instructions: 0.55 us min. \/ Special instructions: 4.1 us min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Processing Time\u003c\/td\u003e\n\u003ctd\u003e0.4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd\u003e10K steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Block Definitions\u003c\/td\u003e\n\u003ctd\u003e128 max. definitions (256 max. instances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Block Languages\u003c\/td\u003e\n\u003ctd\u003eLadder Diagram, Structured Text (ST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTask Configuration\u003c\/td\u003e\n\u003ctd\u003e288 total (32 cyclic tasks, 256 interrupt tasks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Memory Area\u003c\/td\u003e\n\u003ctd\u003eCIO 0 to CIO 99 (1,600 bits \/ 100 words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork Memory Bits\u003c\/td\u003e\n\u003ctd\u003eW0 to W511 (8,192 bits \/ 512 words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIO Area Extension\u003c\/td\u003e\n\u003ctd\u003eCIO 3800 to CIO 6143 (37,504 bits \/ 2,344 words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding Memory Area\u003c\/td\u003e\n\u003ctd\u003eH0 to H511 (8,192 bits \/ 512 words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimers \/ Counters\u003c\/td\u003e\n\u003ctd\u003e4,096 Timers (T0 to T4095) \/ 4,096 Counters (C0 to C4095)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counters\u003c\/td\u003e\n\u003ctd\u003e100 kHz, 4 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt Inputs\u003c\/td\u003e\n\u003ctd\u003e6 inputs (0.3 ms response time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick-Response Inputs\u003c\/td\u003e\n\u003ctd\u003e6 points (min. input pulse width 50 us max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile Backup\u003c\/td\u003e\n\u003ctd\u003eFlash memory for program\/parameters; Battery backup for Holding Area, DM Area, and counter flags\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life Expectancy\u003c\/td\u003e\n\u003ctd\u003e5 years at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Determinism and Backplane Bus Processing\u003c\/h3\u003e\n\u003cp\u003eThe Omron CP1L-M60DR-A architecture utilizes a cyclic scan processing routine optimized for high-speed industrial control execution. Memory allocation for user ladder programs and structured text function blocks runs directly on flash and internal RAM execution planes, yielding minimum basic instruction speeds of 0.55 microseconds.\u003c\/p\u003e\n\u003cp\u003eDeterminism across localized machine processes is maintained via built-in high-speed counters (up to 100 kHz across 4 axes) and dedicated hardware interrupt inputs configured with response times down to 0.3 milliseconds. Up to 3 expansion I\/O units can be connected to the dedicated lateral backplane bus interface. The expansion interface executes immediate refreshing to keep I\/O update latency minimal across up to 180 physical I\/O points.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CP1L-M60DR-A Programmable Controller Unit\u003c\/li\u003e\n\u003cli\u003e1x Removable Terminal Block Assembly (Pre-mounted)\u003c\/li\u003e\n\u003cli\u003e1x Lithium Battery (Installed or separate protective pouch)\u003c\/li\u003e\n\u003cli\u003e1x CP1L Hardware Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting:\u003c\/strong\u003e Install the unit vertically onto a standard 35 mm DIN rail. Ensure at least 50 mm of vertical clearance above and below the controller chassis for natural convection heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring:\u003c\/strong\u003e Wire the 100 to 240 VAC mains supply line to the dedicated AC power input terminals. Use stranded copper conductors rated for at least 75 deg C and torque terminal screws to 0.5 N-m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Setup:\u003c\/strong\u003e Connect a dedicated ground conductor (1.25 mm sq min.) directly to the protective earth terminal on the CPU unit. Ensure earth impedance remains below 100 ohms to minimize common-mode noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Shielding:\u003c\/strong\u003e Ground all shielded cables for high-speed input signals at a single point near the PLC chassis using a 360-deg grounding clamp to suppress high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Output Wiring:\u003c\/strong\u003e Install inductive load suppressors (RC networks for AC loads, flyback diodes for DC loads) across switched output devices to prevent contact arcing and voltage transients from corrupting internal CPU logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat program memory capacity is available on the CP1L-M60DR-A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CPU unit provides 10K steps of non-volatile program memory for ladder logic and structured text definitions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many total physical I\/O points can this controller support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features 60 built-in I\/O points and supports up to 180 total I\/O points when equipped with 3 CP-series expansion units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum execution speed for basic ladder instructions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasic instructions execute at a minimum speed of 0.55 microseconds, while special instructions execute at 4.1 microseconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are holding data and counter states preserved during power loss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn internal lithium battery retains data in the Holding Area, DM Area, and counter registers, delivering up to a 5-year life at 25 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat programming languages are supported within Function Blocks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFunction block definitions support standard Ladder Diagram execution as well as IEC 61131-3 Structured Text (ST).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operational frequency of the built-in high-speed counters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe processor includes 4 axes of built-in high-speed counters operating at frequencies up to 100 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow fast do the quick-response input terminals react?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe quick-response inputs capture narrow pulses down to a minimum input pulse width of 50 microseconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan transistor pulse outputs be driven directly from this specific model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the CP1L-M60DR-A utilizes mechanical relay outputs. Pulse output functionalities require CPU models equipped with transistor outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306615161005,"sku":"CP1L-M60DR-A","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CP1L-M60DR-A_1.jpg?v=1788842916","url":"https:\/\/www.maxwellplc.com\/ga\/products\/omron-cp1l-m60dr-a-cp1l-series-programmable-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}