{"product_id":"omron-cp1l-m40dt-a-cp1l-series-programmable-controller","title":"Omron CP1L-M40DT-A CP1L Series Programmable Controller","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CP1L-M40DT-A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP1L-M40DT-A\u003c\/strong\u003e Programmable Controller, operates as a dedicated hardware component for high-speed sequential execution, high-speed pulse motion control, and discrete logic execution within Omron CP1L automation architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Prefix (CP1L):\u003c\/strong\u003e Compact programmable controller platform with ladder and structured text execution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU Architecture (M):\u003c\/strong\u003e Standard CPU unit with 40 built-in I\/O points and expansion bus interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Capacity (40):\u003c\/strong\u003e 40 total built-in I\/O points (24 discrete inputs, 16 discrete outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type (DT):\u003c\/strong\u003e Transistor sinking outputs supporting high-speed pulse train generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply (A):\u003c\/strong\u003e 100 to 240 VAC power supply input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1L-M40DT-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.610 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 11.0 cm x 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e18.0 cm x 14.0 cm x 11.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 VA max. at 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e24 DC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e16 transistor outputs (sinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counters\u003c\/td\u003e\n\u003ctd\u003e100 kHz (4 axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Outputs\u003c\/td\u003e\n\u003ctd\u003e100 kHz (2 axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd\u003e10K steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Instruction Execution Time\u003c\/td\u003e\n\u003ctd\u003e0.55 us min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial Instruction Execution Time\u003c\/td\u003e\n\u003ctd\u003e4.1 us min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectable Expansion Units\u003c\/td\u003e\n\u003ctd\u003e3 CP-series expansion units max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Expandable I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e160 points (40 built-in + 3x 40-point expansion units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Determinism and Backplane Bus Velocity\u003c\/h3\u003e\n\u003cp\u003eThe Omron CP1L-M40DT-A utilizes an integrated processing engine configured for cyclic scan execution with immediate I\/O refreshing routines. Basic instruction execution speeds of 0.55 us min. maintain tight ladder cycle times across 10K step memory configurations. Interrupt processing for up to 256 tasks enables immediate execution routines independent of cyclic scan overhead.\u003c\/p\u003e\n\u003cp\u003eSystem expansion allows direct attachment of up to 3 CP-series expansion units across the internal parallel expansion bus. The backplane bus architecture maintains high signal velocity during cyclic I\/O refresh cycles, ensuring fast memory transfer between expansion registers, CIO I\/O mapping blocks (CIO 0 to CIO 199), and internal function blocks without degrading deterministic logic execution.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CP1L-M40DT-A Programmable Controller Unit\u003c\/li\u003e\n\u003cli\u003e1x Removable Screw Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1x Hardware Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting:\u003c\/strong\u003e Clip the controller onto a standard 35 mm DIN rail (PFP-50N\/PFP-100N). Ensure a minimum clearance of 50 mm above and below the chassis for proper thermal convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Connections:\u003c\/strong\u003e Wire 100 to 240 VAC power input lines to terminals L1 and L2\/N using stranded copper conductors. Fasten terminal screws to a torque rating of 0.5 N-m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransistor Output Wiring:\u003c\/strong\u003e Wire external load circuits using a sinking configuration. Connect the external DC voltage source positive rail to the load and the negative side to the controller terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Setup:\u003c\/strong\u003e Wire the protective earth (PE) terminal directly to an earth ground point with a dedicated conductor having an impedance under 100 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Procedures:\u003c\/strong\u003e Terminate high-speed input and pulse output signal cable shields at a single ground point using 360-deg braid grounding clamps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat output device type is incorporated on the CP1L-M40DT-A chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CP1L-M40DT-A features 16 transistor sinking outputs rated for high-speed switching and pulse train generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input and output point counts are provided on the CPU unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe main controller chassis incorporates 24 discrete DC inputs and 16 transistor outputs, totaling 40 built-in I\/O points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat high-speed pulse output functionality does the controller support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CPU provides 2 axes of high-speed pulse train outputs operating at frequencies up to 100 kHz for motion control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating power supply voltage is required for controller operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller operates on an internal wide-range AC power supply accepting 100 to 240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many CP-series expansion units can be added to the CPU base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA maximum of 3 CP-series expansion units or expansion I\/O units can be attached via the expansion bus port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat basic instruction execution speed is achieved by the CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe processing unit executes basic ladder instructions at a minimum speed of 0.55 microseconds per instruction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many function block definitions can be stored in program memory?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe application logic memory supports up to 128 function block definitions and up to 256 active instances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat shielding guidelines must be followed for pulse output wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePulse output signal cables must use shielded twisted-pair lines terminated with 360-deg braid clamps to PE ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306644750509,"sku":"CP1L-M40DT-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CP1L-M40DT-A_1.jpg?v=1788843188","url":"https:\/\/www.maxwellplc.com\/ga\/products\/omron-cp1l-m40dt-a-cp1l-series-programmable-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}