{"product_id":"omron-cp1e-n60s1dr-a-programmable-controller-cp1e-series","title":"Omron CP1E-N60S1DR-A Programmable Controller CP1E Series","description":"\u003cp\u003eConfigured for high-density discrete switching and serial communications in industrial logic architectures, the \u003cstrong\u003eOmron CP1E-N60S1DR-A\u003c\/strong\u003e (\u003cstrong\u003eCP1E-N60S1DR-A\u003c\/strong\u003e Programmable Controller) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model Family:\u003c\/strong\u003e CP1E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass Variant:\u003c\/strong\u003e N (Application model with motion\/serial functionality)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e 60 points (36 DC inputs, 24 relay outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign Version:\u003c\/strong\u003e S1 (Renewal type with built-in RS-485 port)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Serial Interface:\u003c\/strong\u003e 1x Built-in RS-485 port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Architecture:\u003c\/strong\u003e D (24 VDC inputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Configuration:\u003c\/strong\u003e R (Electromechanical relay outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Class:\u003c\/strong\u003e A (100 to 240 VAC power supply)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1E-N60S1DR-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.5 cm x 11.0 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e23.0 cm x 15.0 cm x 12.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 VA max. at 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd\u003e8K steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory Capacity\u003c\/td\u003e\n\u003ctd\u003e8K words (DM Area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Serial Ports\u003c\/td\u003e\n\u003ctd\u003e1x USB (Peripheral), 1x RS-485 (2-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counters\u003c\/td\u003e\n\u003ctd\u003e6 axes (100 kHz single-phase \/ 50 kHz differential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOmron PLC Backplane Bus \u0026amp; Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe CP1E-N60S1DR-A renewal application CPU interfaces integrated I\/O blocks using an internal high-velocity logic bus, eliminating scanning latencies across its 36 DC input and 24 relay output circuits. The built-in RS-485 port operates directly through the CPU core, executing Modbus-RTU easy master commands and Serial PLC Link communications without requiring external serial option boards. Program execution occurs via non-volatile flash memory updates, maintaining cyclic scan times while servicing high-speed counter interrupts and RS-485 serial packet queues.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CP1E-N60S1DR-A CPU Unit\u003c\/li\u003e\n\u003cli\u003e1x Screw terminal cover plate assembly\u003c\/li\u003e\n\u003cli\u003e1x Hardware installation instruction manual sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Latch the controller onto a standard 35 mm DIN rail (TH35-7.5\/TH35-15). Retain at least 50 mm clearance above and below the housing to maintain convection airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Supply Wiring:\u003c\/strong\u003e Connect 100 to 240 VAC power conductors (AWG 14 to AWG 18) to terminals L1 and L2\/N. Torque terminal block screws to 0.5 N m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-485 Shielding \u0026amp; Termination:\u003c\/strong\u003e Wire 2-wire RS-485 networks using twisted pair shielded cabling. Connect a 120 Ohm (1\/2 W) terminating resistor across terminals A and B at both ends of the physical bus line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarthing Procedure:\u003c\/strong\u003e Connect the functional ground (FG) terminal to an earth ground electrode with a resistance below 100 Ohm using a minimum 2.0 mm2 conductor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the built-in RS-485 interface support 4-wire full-duplex communication?\u003c\/p\u003e\n\u003cp\u003eNo. The built-in RS-485 port on the S1 renewal model is hardwired for 2-wire half-duplex communication protocols such as Modbus-RTU and Serial PLC Link.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted for connected expansion units or terminal blocks?\u003c\/p\u003e\n\u003cp\u003eNo. Main supply power must be fully disconnected before modifying screw terminal connections or adding local CP1W expansion modules to avoid backplane damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat digital input filtering time constants can be configured in CX-Programmer?\u003c\/p\u003e\n\u003cp\u003eThe hardware input filter delay is software-configurable from 0 ms (no filter) up to 32 ms to eliminate contact bounce from external field switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat memory area retains program register states during long-term power outages?\u003c\/p\u003e\n\u003cp\u003eUser ladder logic programs and parameter settings store directly to non-volatile flash memory, while DM registers and counter values are preserved via battery backup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum wire size is supported by the built-in I\/O terminal screws?\u003c\/p\u003e\n\u003cp\u003eThe integrated M3 terminal screws accept solid or stranded copper conductors ranging from 0.08 mm2 to 2.0 mm2 (AWG 28 to AWG 14) fitted with crimp ferrules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response frequency for high-speed counter inputs on this CPU?\u003c\/p\u003e\n\u003cp\u003eHigh-speed counter inputs process single-phase pulse inputs up to 100 kHz, or differential phase-difference pulse inputs up to 50 kHz across 6 dedicated axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the relay outputs directly drive inductive loads without external suppression?\u003c\/p\u003e\n\u003cp\u003eRelay contacts switch up to 2 A at 250 VAC \/ 24 VDC resistive, but inductive loads require external RC surge absorbers (AC) or freewheeling diodes (DC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat derating factor applies when operating near the 55 deg C upper thermal limit?\u003c\/p\u003e\n\u003cp\u003eAt an ambient operating temperature of 55 deg C, the simultaneous ON ratio of all combined digital input and relay output points must not exceed 80 percent max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306675028141,"sku":"CP1E-N60S1DR-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_cp1e-n60s1dr-a_1.jpg?v=1788535017","url":"https:\/\/www.maxwellplc.com\/ga\/products\/omron-cp1e-n60s1dr-a-programmable-controller-cp1e-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}